Ambient temperature
Storage temperature, min.
Humidity, max.
Supply voltage, plant
Control for Media filter (only WPC 100 FW-AM)
Dosing pumps
Electrical fuses
Electrical connection value
Raw water temperature
Reference temperature
pH value fo raw water
pH value of plant cleaning
Inlet pressure of raw water
Output range
Drinking water output, max.
Efficiency rating*
Dimensions (h x b x d)
Weight in delivered state (without filter fillings)
Max. salt content in raw water
Manufacturer
*Efficiency rating means the percentage of the influent water to the system that is available to the user as reverse osmosis
treated water under operating conditions that approximate typical daily usage.
Warranty
The warranty terms published by our
competent sales company are applica-
ble in each country. We will repair po-
tential failures of your appliance within
the warranty period free of charge, pro-
vided that such failure is caused by
faulty material or defects in fabrication.
In the event of a warranty claim please
contact your dealer or the nearest au-
thorized Customer Service center.
Please submit the proof of purchase.
Specifications
Spare parts
For additional information about spare
parts, please go to the Service section
at www.kaercher.com.
°C (°F)
°C (°F)
% rel.
V/Hz
V/Hz
prim.: 240/1~60, sec.: 12/1~60
V/Hz
A
kW
°C (°F)
°C (°F)
MPa (psi)
l/day (gal/day)
l/h (gal/h)
%
mm
kg (lbs)
ppm
Alfred Kärcher GmbH & Co. KG
Cleaning Systems
Alfred-Kärcher-Str. 28-40
P.O. Box 160
D - 71349 Winnenden
Telephone: +49 7195 14-0
Telefax: +49 7195 14-2212
+1...+50 (34...122)
–10 (14)
100
240/1~60
220...240/1~60
15
0,4
+5...+35 (41...95)
+15 (59)
6...9,5
3...11
0,2...0,6 (29...87)
2400±15% (634±15%)
100 (26,4)
60...80
1200 x 450 x 430
55 (121)
1000
English
9