UNIT INSTALLATION
DSW15 & RSW2/ DSW16 & RSW1: Not used
Factory setting
(Do not change)
SSW1: Remote/Local
Factory setting
(Remote operation)
Local operation
6 UNIT INSTALLATION
6.1 GENERAL NOTES
6.1.1 Components at receipt
Outdoor unit
?
N O T E
For outdoor unit installation information, please refer to the outdoor unit
Installation and operational manual.
6.1.2 Selection of the installation location
The indoor unit of the split system with air to water heat pump
must be installed following these basic requirements:
•
The indoor unit is intended to be installed in an indoor place
and for ambient temperatures ranging 5~30°C. The ambient
temperature around the indoor unit must be >5°C to prevent
water from freezing.
•
The indoor unit is prepared to be floor mounted, so make
sure that selected floor is flat and is made of a non-
combustible surface, strong enough for supporting the
indoor weight and also the DHW tank's weight completely
water filled.
•
Be sure to maintain the recommended servicing space for
future unit servicing and guarantee enough air circulation
around the unit (See
"3.1.3 Model for UK market"
•
Take into account that two shut-down valves (factory
supplied) must be installed at the indoor unit inlet/outlet
21
PMML0338B rev.1 - 03/2016
All manuals and user guides at all-guides.com
Factory setting
(Heat operation)
Cool and Heat operation in case of Local
5.6.3 LED indication
Remote
Local
Remote
Local
Indoor unit
•
•
•
•
•
•
•
•
•
•
•
•
section).
•
SSW2: Heat/Cool
Name
Colour
LED1
Green
Power indication
LED2
Red
Power indication
LED3
Red
Heat pump operation (thermo ON/OFF)
LED4
Yellow
Alarm (flickering with 1 sec interval)
LED5
Green
Not used
LED6
Yellow
H-Link transmission
LED7
Yellow
H-Link transmission for unit controller
connections.
Take into account the space needed to install a necessary
pressure and temperature relief valve, which must be
installed at the DHW inlet connection of the tank (as close as
possible to the tank). 1 shut-down valve (field supplied) must
be also installed at the DHW outlet connection (See
"4.3 Space heating and
DHW").
Keep water draining provisions. The safety valve and the air
purge are provided with a drain pipe which are located at the
bottom side of the unit.
For UK market models is strongly adviced that a safe place
is needed for discharging of high temperature and high pres-
sure water and steam from the pressure and temperature
relief valve. Refer to UK Building Requirements for a correct
safe drain.
If the event of installing the "Cooling kit" accessory, the
installer is responsible for proper installation and draining.
Protect the indoor unit against the entry of small animals
(like rats) which could making contact with the wires, the
drain pipe, electrical parts and may damage unprotected
parts, and at the worst, a fire will occur.
Install it in a no-frost environment.
Do not install the indoor unit in a location with very high
humidity.
Do not install the indoor unit where electromagnetic waves
are directly radiated to the electrical box.
Install the unit in a place where in case of water leakage,
any damage to the installation space cannot be produced.
Install noise filter when the power supply emits harmful
noises.
To avoid fire or explosion, do not install the unit in a
flammable environment.
The air to water heat pump must be installed by a service
technician. The installation must comply with local and
European regulations.
Try to avoid to put any objects or tools above the indoor unit.
Heat
Cool
Heat
Cool
Indication