process. The trim is wrapped separately and
taped to the top of the unit.

Electrical Requirements

Ensure that dedicated circuit protection is
prepared as recommended and that the appliance
is grounded properly.
• This wall oven must be electrically grounded in
accordance with local codes or, in their absence,
with the National Electrical Code ANSI/NFPA
Category
Single wall oven
Double wall oven
Category
Single wall oven
Double wall oven
WARNING
• DO NOT ground to a gas pipe.
• DO NOT have a fuse in the neutral or grounding
circuit.
• A UL-listed conduit connector must be provided
at the junction box.
• The appliance must be hard wired (direct wired)
into an approved junction box. A plug and
receptacle is not permitted on these products.
• DO NOT shorten the flexible conduit. The
conduit connector must be securely attached to
the junction box and the flexible conduit must be
securely attached to the conduit connector. If
the flexible conduit will not fit within the
connector, do not install the oven until a
connector of the proper size is obtained.
NOTE
• The power leads supplied with the appliance are
UL, CSA recognized for connection to larger
gauge household wiring. The insulation of these
leads is rated at temperatures much higher than
the temperature rating of household wiring. The
current carrying capacity of the conductor is
governed by the wire gauge and the
Appliance rating Watts 240 V
Power consumption
4100 W
8200 W
Appliance rating Watts 208 V
Power consumption
3100 W
6100 W
No.70- latest edition* in United States, or with
CSA Standard C22.1-1982 and C22.2 No.01982
(or latest edition)**, Canadian Electrical Code,
Part1, and all local codes and ordinances.
• This wall oven must be supplied with the proper
voltage and frequency, and connected to an
individual, properly grounded branch circuit,
protected by a circuit breaker or fuse. To know
the circuit breaker or fuse required by this
model, see the rating plate to find the wattage
consumption and refer to the table below to get
the circuit breaker or fuse amperage.
Protection circuit
recommended
30 A
50 A
Protection circuit
recommended
20 A
40 A
temperature rating of the insulation around the
wire.
• You will need to purchase an appropriate
conduit connector to complete the connection of
the conduit to the junction box.

Making Electrical Connections

WARNING
• New branch-circuit installations (1996 NEC),
mobile homes, recreational vehicles, or
installations where local codes prohibit
grounding through the neutral conductor
require 4-wire branch-circuit connection.
• Improper connection of aluminum house wiring
to copper leads can result in an electrical hazard
or fire. Use only connectors designed for joining
copper to aluminum and follow the
manufacturer's recommended procedure
closely.
1
Turn off the circuit breaker or remove fuses to
the oven branch circuit.
INSTALLATION
13
Wire gauge
recommended
12 AWG
10 AWG
Wire gauge
recommended
12 AWG
10 AWG