10 Anexo
Report Number of Floats
Parámetro
Request:
Set Receive to Transmit
Delay
Response:
Set Receive to Transmit
Delay
Report Receive to Transmit Delay
Parámetro
Request:
Report Receive to Transmit
Delay
Response:
Report Receive to Transmit
Delay
Código de error
Error Code
EE-Error
FR-Error
LV-Error
10.6 Configuración de un host Modbus típico
Fisher ROC 809
Fig. 40: Conexión del VEGABAR 83 a RTU Fisher ROC 809
1
VEGABAR 83
2
RTU Fisher ROC 809
3
Alimentación de tensión
80
Length
4 characters ASCII
5 characters ASCII
Length
4 characters ASCII
7 characters ASCII
Name
Error While Storing Data in EEPROM
Erorr in Frame (too short, too long, wrong data)
Value out of limits
(Rx/Tx -)
B
(Rx/Tx +)
A
Y
Z
COM
+8
Vdc
GND
VEGABAR 83 • Protocolo Modbus y Levelmaster
Code/Data
UuuF
UuuFn
n = number of measurement values
(0, 1 or 2)
Code/Data
UuuR
UuuRmmm
mmm = milliseconds (50 up to
250), default = 127 ms
2
+30
to
3