Installation
Table of sizes (fig. 4)
•
The closer is shipped set to size 3. To change
the closer size, use a hex wrench to rotate the
spring power adjust. Follow the chart to make the
correct number of 360° turns to set the closer size
appropriately for the door application.
•
The number of turns is an approximation and does not
account for environmental or door hardware effects.
Exterior (and vestibule) door width
24"
(610 mm)
Regular arm
and top jamb
Parallel arm
24"
30"
(610 mm)
(762 mm)
Regular
Size 1
arm and
(10 CCW)
top jamb
Parallel
Size 1
arm
(5 CCW)
CW = clockwise
CCW = counterclockwise
Minimum door width (24")
30"
(762 mm)
(914 mm)
Size 3
(0)
Size 3
(5 CW)
Interior door width
Minimum door width (24")
34"
(865 mm)
(965 mm)
Size 2
(5 CCW)
Size 2
(0)
36"
42"
(1067 mm)
Size 4
(5 CW)
Size 4
(10 CW)
38"
48"
(1,219 mm)
Size 3
Size 4
(0)
(5 CW)
Size 3
Size 4
(5 CW)
(10 CW)
48"
(1,219 mm)
Size 5
Size 6
(10 CW)
(15 CW)
Size 5
(15 CW)
54"
(1,372 mm)
(1524 mm)
Size 5
Size 6
(10 CW)
(15 CW)
Size 5
(15 CW)
60"