Note: when switched on, the breast pump always starts
in stimulation mode to facilitate milk extraction, using the
factory settings (level 5). The stimulation indicator (24) will
appear on the display.
Note: To avoid all danger deriving from spilt liquid (milk), we
recommend that you never fill the feeding bottle beyond
the highest level indicated on its graduated scale.
Single Mode
000091993000000 and
• Fit the cup over your breast ensuring that the nipple is
centred properly. You can use the breast pump both with
and without the soft silicone cover (3). We recommend
trying both configurations before choosing the best and
most comfortable one for you. Press the on/off button (13)
on the motor body (10) to switch on the breast pump, the
display (11) will light up.
• Only for 000091994000000 - check the icon (26) that indi-
cates which operating mode is active on the breast pump.
For single mode the icon shows a single circle. If this is not
the case, press the buttons "+" (15) and "-" (14) at the same
time to change the breast pump operating mode from
double (two circles) to single (one circle).
If you are using the breast pump powered by alkaline bat-
teries, the indicator on the display will show the battery
charge status (21). If it is powered by the mains adaptor,
this indicator will not appear. The battery indicator shows 4
levels based on the battery charge status.
• After approximately 2 minutes of stimulation, the appli-
ance automatically switches to the extraction mode using
the factory settings (level 5). The extraction indicator (25)
will appear on the display.
• You can stop the stimulation stage and switch to the ex-
pression stage by briefly pressing the stimulation/extrac-
tion button (16).
• If necessary, repeat stimulation by pressing the stimula-
tion/extraction button (16) again. Press the stimulation/
extraction button (16) to return to extraction.
• You can use the "+" (15) and "-" (14) buttons on the keypad
to adjust extraction/stimulation based on the level of pull
felt on your breast and/or based on the amount of milk
expressed. We recommend adjusting the extraction/stim-
ulation rate gradually until you reach the level best suited
to you.
• If the level of extraction/stimulation chosen causes dis-
comfort or pain, reduce it to a suitable level by pressing
the "-" button (14).
• You can alternate milk extraction from both breasts.
• Press the on/off button (13) to switch the breast pump off.
• When the breast pump is switched back on it will be set to
the stimulation/extraction levels stored from the previous
session.
Double Mode - only for
• Press the on/off button (13) on the motor body (10) to
switch on the breast pump, the display (11) will light up.
• Press the buttons "+" (15) and "-" (14) at the same time to
change the breast pump operating mode from single
(factory setting) to double. The icon (26) that indicates the
breast pump operating mode must show two circles for
double mode.
• Fit the cup over your breast ensuring that the nipple is
000091994000000
000091994000000
centred properly.
• Fit the second cup over your second breast, ensuring that
the nipple is centred properly.
• After approximately 2 minutes of stimulation, the appli-
ance automatically switches to extraction mode using the
factory settings (level 5). The extraction indicator (25) will
appear on the display.
• You can stop the stimulation stage and switch to the ex-
pression stage by briefly pressing the stimulation/extrac-
tion button (16).
• If necessary, repeat stimulation by pressing the stimula-
tion/extraction button (16) again. Press the stimulation/
extraction button (16) to return to extraction.
• You can use the "+" (15) and "-" (14) buttons on the keypad
to adjust extraction/stimulation based on the level of pull
felt on your breast and/or based on the amount of milk
expressed. We recommend adjusting the extraction/stim-
ulation rate gradually until you reach the level best suited
to you.
• If the level of extraction/stimulation chosen causes dis-
comfort or pain, reduce it to a suitable level by pressing
the "-" button (14).
• Press the on/off button (13) to switch the breast pump off.
• When the breast pump is switched back on it will be set to
the stimulation/extraction levels stored from the previous
session.
• WARNING: immediately after each single use, carefully
clean all the components* as shown in the "CLEANING"
paragraph.
• To feed the milk immediately to your baby, unscrew the
feeding bottle from the pump body (4) to remove it.
Screw the ring with the teat (7) (included in the pack)
onto the feeding bottle. This way, you will obtain a handy,
ready-to-use baby feeding bottle.
• If, on the contrary, you close the bottle with the airtight
cap (8) (included in the package) you can store the ex-
pressed milk in the fridge for up to 48 hours at 4°C or for
up to 3 months at -18°C in the freezer.
• WARNING: When the breast pump is not used, always
disconnect the mains adaptor from the mains.
*Excluding the motor body (10) and mains adaptor (19) and
the silicone tubes (17) or (18).
CLEANING
• Before carrying out any cleaning operation, disconnect,
if connected, the mains adaptor from the mains and the
power cord connector from the socket (20) on the motor
body.
• Separate all the components from the breast pump.
Note: remove the valve (5), located on the circular conduit
in the pump body (4) by gently pulling the tab on the side
of the valve.
• WARNING: Make sure that the valve is always removed in
a gentle way; do not use any tool for cleaning it because
it may be damaged, making the breast pump impossible
to use.
Note: to remove the silicone tube, first detach the mem-
brane (1) and the membrane cover from the pump body,
to avoid any spillage. Then, holding the end inserted into
the membrane cover, gently pull it off.
• Carefully wash all the components* using hot water and
washing up liquid, thoroughly rinse and dry carefully us-
23