SICK WTF26 Manual Del Usuario página 25

Ocultar thumbs Ver también para WTF26:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 32
8025684.1DS8/2021-11-24 | SICK
Subject to change without notice
The sensing range is adjusted by pressing the teach-in button (approx. 1-3 seconds).
Depending on the requirements, the potentiometer can be used for fine-tuning (without
pressing the teach-in button).
Clockwise rotation: Sensing range increased
Counterclockwise rotation: Sensing range reduced
The sensing range can also be adjusted using just the potentiometer.
1.
1...3 sec.
2.
The conveyor belt should now be put into operation without any objects. If the
yellow LED indicator lights up permanently during the test run, the sensing range is
set correctly.
3.
If the yellow LED indicator does not light up briefly during the test run, reduce the
sensing range minimally. This increases the minimum object height accordingly.
Then check the detection with the object.
WTF26x-xxxxxx1xAxx with potentiometer:
The sensing range is adjusted with the potentiometer.
Clockwise rotation: Sensing range increased
Counterclockwise rotation: Sensing range reduced
COMMISSIONING
O P E R A T I N G I N S T R U C T I O N S | WTF26
7
en
25

Publicidad

Tabla de contenido
loading

Tabla de contenido