Press
to set the desired temperature. The temperature will increase
1°C for each time the button is pressed. When the top value for the zone is
reached, it will continue from the lowest value of the zone.
•
After 5 seconds the display will switch back to show actual temperature
Operation
Control Panel
FWK 16177
Dual Zone
1
Lighting
2
Upper zone
3
Temperature upper zone 10
4
°C / °F
5
Temperature lower zone
6
Setting "Up"
7
Setting "Down"
Power On/Off
•
When the appliance is plugged in to a power outlet, it powers on automati-
cally. To power OFF, the plug have to be unplugged.
Temperature setting
•
The temperature setting ranges are 5-12 ºC for the upper zone and 12-22 ºC
for the bottom zone.
•
Chose zone to adjust by pressing once on: "UP" for upper zone "DOWN" for
lower zone The display with digital flashing indicates the zone ready for tem-
perature setting.
•
Press "UP" or "DOWN" to set the desired temperature. The temperature will
change 1°C for each time the button is pressed. After 5 seconds, the display
will switch back to show actual temperature in the zone.
Warning
•
To avoid breaking the compressor, please do not turn on the appliance again
within 5 minutes after you turn it off.
•
If the unit is unplugged, power lost, or turned off, you must wait 3 to 5
minutes before restarting the unit. If you attempt to restart before this time
delay, the Wine cooler will not start.
Interior lighting On/Off
•
Touch the lighting button to turn on (or turn off) the interior cool LED
lighting.
•
The lighting will be continuously on if it is not turned off except for FWK
16177 where it will automatically switch off after 20 minutes. BWK 1607 &
BWK 1622 where it will automatically switch off after 10 minutes.
8
Lower zone
9
°C / °F
Light "Compressor working"
11
Light "Heating working"
12
°C / °F interchange
4