RJG MCSG‑B‑159‑4000 Manual Del Producto página 29

Tabla de contenido

Publicidad

ESPECIFICACIONES DE INSTALACIÓN (continuación)
Drawing Title: MCSG-B-159-4000-08
INSTALACIÓN DE LA PLACA DEL EYECTOR
M
NOTES:
1.
CLAMP PLATE APPLICATIONS REQUIRE GUIDED EJECTION
2.
EJECTOR AND TRANSFER PIN CONCENTRICITY MUST BE WITHIN 0.030" [0.76] OR
10% OF EJECTOR PIN DIA, WHICHEVER IS SMALLER.
3.
ENCLOSED EJECTOR BOX SUGGESTED.
4.
DO NOT SCALE PRINT
5.
BREAK ALL SHARP EDGES, 0.005 [0.03] R MAX
6.
DIMENSIONS IN INCHES [MM], UNLESS NOTED
7.
TOLERANCES UNLESS SPECIFIED:
XXX = 0.003 [0.08]
XX = 0.01 [0.3]
ANGLES = 3 30
Manual del Producto | Sensor de Button de 4.000 Libras de Galga Extensométrica Multicanal Lynx™ MCSG‑B‑159‑4000
Multi-Channel Strain Gage 4,000 lb. Sensor (MCSG-B-159-4000) Installation—Ejector Plate Installation
B-Plate or Cavity Insert
Ejector Pin Installed with Normal
Slip-Fit Tolerances H7/g6
Ejector Retainer Plate
0.001 [0.03] N
0.001 [0.03]
Ejector Plate
0.001 [0.03] O
0.001 [0.03]
Clamp Plate
Ejector Pin Ø
0.04–0.08 [1.0–2.0]
0.10–0.20 [2.5–5.0]
0.24–0.40 [6.0–10.0]
0.01 MIN
0.3 MIN
Per Side
0.635
[16.13 0.1]
N
O
45°
REFER TO
TABLE P
DETAIL M
TABLE P
SCALE 3 : 1
Chamfer Length
0.01 [0.3]
0.02 [0.4]
0.025 [0.6]
Ejector Pin Ø + 0.125 [3]
IF Ø ≥0.50 [12.7]
+
0.005
-
0.000
Part Thickness < 0.05 [1.5], 1/5 of Thickness
Part Thickness > 0.05 [1.5], 0.01 [3.0]
0.02 MIN
+
0.500
[12.7 0.04]
R0.005
0.1
0.5 MIN
0.002
-
0.001
Description: MCSG-B-159-
4000 Sensor Installation
Drawn: K.J.Brettschneider
Design:
Check: M.Groleau
Date: 12.02.2021
RJG, Inc.
21