Descargar Imprimir esta página

Reer mosaic MA2 Guía De Instalación Rápida página 2

Publicidad

MA2 / MA4
C) MORSETTIERE - TERMINAL BLOCKS - BORNIERS - ANSCHLUSSKLEMMEN - TERMINALES
PIN
10
11
12
13
14
15
16
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
 Refer to the manual for wiring details in the different operation mode
D) CONNESSIONE SENSORI - SENSORS CONNECTION - CONNEXION DES CAPTEURS - ANSCHLUSS DER SENSOREN - CONEXIÓN DE SENSORES
 If shielded cables are not used or if the shield connection to PE is not properly wired then electromagnetic disturbance could cause signal corruption. A corrupted
signal could lead to unexpected behavior of the module which as a consequence could lead to potentially severe damage to people or things.
 If the sensor connections are not correct or if the type of sensor connected to the input is incorrect (for example a voltage sensor connected to a current input
and vice versa), the functionality of the module is not more guaranteed.
 Perform a complete system TEST (see "TESTING the system").
R
R S.p.A. Via Carcano 32, 10153 Torino Italia
EE
Tel. +39 0112482215 r.a. Fax +39 011859867
Sito web: www.reersafety.com - email: info@reer.it
SIGNAL
TYPE
1
24VDC
2
NODE_SEL0
Input
3
NODE_SEL1
Input
4
0VDC
9
24VDC_S1
Output
IN_S1
Input
NEG_S1
OUT_S1
Output
POS_S1
Input
0VDC_S1
Output
24VDC_S2
Output
IN_S2
Input
NEG_S2
OUT_S2
Output
POS_S2
Input
0VDC_S2
Output
9
24VDC_S1
Output
IN_S1
Input
NEG_S1
OUT_S1
Output
POS_S1
Input
0VDC_S1
Output
24VDC_S3
Output
IN_S3
Input
NEG_S3
OUT_S3
Output
POS_S3
Input
0VDC_S3
Output
24VDC_S2
Output
IN_S2
Input
NEG_S2
OUT_S2
Output
POS_S2
Input
0VDC_S2
Output
24VDC_S4
Output
IN_S4
Input
NEG_S4
OUT_S4
Output
POS_S4
Input
0VDC_S4
Output
NODE 0
NODE 1
NODE 2
NODE 3
DESCRIPTION
-
24VDC power supply
Node selection
(see following table)
-
0VDC power supply
MA2
Sensor 1 connections
Sensor 2 connections
MA4
Sensor 1 connections
Sensor 3 connections
Sensor 2 connections
Sensor 4 connections
CONFIGURATION NODE SEL
NODE_SEL0 (PIN 2)
0 (or not connected)
24VDC
0 (or not connected)
24VDC
QUICK INSTALLATION GUIDE
OPERATION
-
Input ("type B" according to EN 61131-2)
Input ("type B" according to EN 61131-2)
Isolated 24VDC power supply for sensor 1
4/20mA sensor 1 Input
0/10V sensor 1 negative input
4/20mA sensor 1 Output
0/10V sensor 1 positive input
Isolated 0VDC reference for sensor 1
Isolated 24VDC power supply for sensor 2
4/20mA sensor 2 Input
0/10V sensor 2 negative input
4/20mA sensor 2 Output
0/10V sensor 2 positive input
Isolated 0VDC reference for sensor 2
Isolated 24VDC power supply for sensor 1
4/20mA sensor 1 Input
0/10V sensor 1 negative input
4/20mA sensor 1 Output
0/10V sensor 1 positive input
Isolated 0VDC reference for sensor 1
Isolated 24VDC power supply for sensor 3
4/20mA sensor 3 Input
0/10V sensor 3 negative input
4/20mA sensor 3 Output
0/10V sensor 3 positive input
Isolated 0VDC reference for sensor 3
Isolated 24VDC power supply for sensor 2
4/20mA sensor 2 Input
0/10V sensor 2 negative input
4/20mA sensor 2 Output
0/10V sensor 2 positive input
Isolated 0VDC reference for sensor 2
Isolated 24VDC power supply for sensor 4
4/20mA sensor 4 Input
0/10V sensor 4 negative input
4/20mA sensor 4 Output
0/10V sensor 4 positive input
Isolated 0VDC reference for sensor 4
NODE_SEL1 (PIN 3)
0 (or not connected)
0 (or not connected)
24VDC
24VDC
2