JUMPERS SETTINGS
1. Delay jumper
Is used to set the alarm delay time. If is set the "Test time" (5
seconds), the alarm is working each 5 seconds after activate it. If is
set the "Work mode" (5 minutes), the alarm is working each 5 minutes
after activate it.
Short 1 y 2: Delay of 5 seconds (Test mode)
Short 2 y 3: Delay of 50 seconds (Test mode)
Short off: Delay of 5 minutes (Work mode)
2. Jumpers of configuration
Is using to have 2 or more sensors paired in the same camera, or
when there are interference. To activate 2 or more sensors, the
jumpers must be in different positions.
The direction code is A0-A7, and must coincide with the alarm.
The defense zone code is D0-D3.
3. Jumper LED
Set the on and off of the LED while the sensor is active.
Short 1 y 2: LED on
Jumper out: LED off
Short off: The LED can closed (turn off) to hide the sensor after the
test.
31