EN
S6
INSTRUCTIONS
PRECISION REV COUNTER
4.2 Resetting the max record
In the max record screen, press and hold the
button for 3 seconds to reset the record.
4.3 Setting Up the Rev Counter
CAUTION!
Be sure to enter the correct stroke and cylinder numbers.
If the input is incorrect, the RPM output will be incorrect, too.
Engines that ignite every 360° are defined as two-stroke and engines that ignite every 720° are defined as four-stroke.
Four-stroke engines with one cylinder that ignite every 360° will have to be treated just like two-stroke engines with one
cylinder.
22
In the main screen, press and hold the button for 3 seconds to enter set-up mode. You can switch between
the different set-up screens (ADJ 1 to ADJ 8) by pressing the button briefly. In order to enter the respective
screen, simply press and hold the button for 3 seconds.
When ADJ 1 appears on the screen, press and hold the button for 3 seconds to enter the ADJ 1 set-up screen.
Press the button once to change the stroke setting.
E.g.: The setting is changed from 2C (two-stroke) to 4C (four-stroke).
NOTE
You can select 2C (two-stroke) or
4C (four-stroke).
The stroke is
flashing.