Desoutter PT240-T2800-I19S Manual De Instrucciones página 53

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 14
General
Tightening of threaded connections
The tightening torques indicated in the spare parts list are established to achieve the correct
clamping force and to prevent the parts from coming loose. When serviced these parts must
be able to open up without being destroyed. In special circumstances (depending on applic-
ation and usage) the parts may however come loose after some time of operation. In such
cases the torque could be increased 10-20% and if necessary some type of low or medium
threadlocking fluid could also be applied.
Example
Operating Instructions
Starting
Position of reversing knob when used by right-handed
+ 10-20% Nm
LOCTITE
Forward
Reversing
Position of reversing knob when used by left-handed
Part no
2050505743
Issue no
3
Series no
C
Date
2015-03
Page
53

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

2051474724

Tabla de contenido