Forced Operation; Sleep Mode - LG SP122CM SY0 Manual Del Propietário

Ocultar thumbs Ver también para SP122CM SY0:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Forced operation

Operation procedures when the remote control can't be used.
The operation will be started if the ON/OFF button is pressed.
If you want to stop operation, re-press the button.
Cooling Model
Operating mode
Cooling
Indoor FAN Speed
Setting Temperature
Test operation
During the TEST OPERATION, the unit operates in cooling mode at high speed fan, regardless of room
temperature and resets in 18 minutes.
During test operation, if remote controller signal is received, the unit operates as remote controller sets.
If you want to use this operation, Press and hold the ON/OFF button for 3~5 seconds, then the buzzer sound
1 "beep".
If you want to stop the operation, re-press the button.

Sleep Mode

1. Press the SLEEP MODE AUTO BUTTON to set the time when you want the unit to stop automatically.
2. The timer is programmed in one-hour increments by pressing the SLEEP MODE AUTO BUTTON 1 to 7 times.
The sleep mode is available for 1 to 7 times.
To alter the time period in steps of 1 hour, press the SLEEP MODE AUTO BUTTON while aiming at air conditioner.
3. • (In case of non-Inverter Model)
Make sure the sleep mode LED lights up.
To cancel the sleep mode, press the SLEEP MODE AUTO BUTTON several times until the sleep mode LED lights off.
NOTE
• The sleep mode will operate indoor fan at slow speed in cooling mode and at medium speed in heating mode for
pleasant sleep.
• Art Cool and Art Cool Wide (non-Deluxe) close the lower discharge partially in sleep mode for pleasant sleep.
In cooling mode or healthy dehumidification mode:
The setting temperature will rise automatically two times by 1°C over next consecutive 30 minutes (2°C in 1 hour) for a
comfortable sleep. Now this will be the final setting temperature as long as sleep mode is functioning.
Room Temp. ≥ 24°C
Cooling
High
High
22°C
22°C
ON/OFF
button
Heat pump Model
21°C ≤ Room Temp. < 24°C
Healthy Dehumidification
High
23°C
Operating Instructions
Room Temp. < 21°C
Heating
High
24°C
Owner's Manual 13

Publicidad

Capítulos

Tabla de contenido
loading