ATTENTION
The stove has been designed to work only with original and quality pellet.
The manufacturer declines all responsibility in the case of using low quality pellet and a not adequate diameter
which may cause a malfunction.
4.3 SAFETY DEVICE:
Thermocouple: located in the exhaust smoke pipe which increases the temperature. According to the established
•
parameters, you can control the power phase by turning on and switching off.
Electromagnetic device: placed in the smoke evacuation duct, it blocks the stove operation when the fire door is
•
opened or when the tube is blocked.
Safety thermostat: positioned below the hopper loader, intervenes in the case in which the temperature exceeds
•
the preset security level, block and pellet loading the heater shuts off.
Safety Thermostat: is located in the power supply. Intervenes in the case the indoor temperature is greater than the
•
safety value, blocking the supply of pellets and shutting down the stove automatically.
4.4 OPERATION
Before turning on the stove, the verification of the following points is required:
•
Deposit must be loaded with pellet. To load it, the top lid must be opened
The combustion chamber must be clean.
•
•
Check the door hermetic seal
Check that the power cord is properly connected to the power supply before pressing the switch.
•
During the first 2-3 ignitions one should pay attention to the following points:
No children must be present during ignition as some gases emitted may be toxic to health. Adults should also
•
avoid prolonged presence beside the stove. It is obligatory to ventilate the stove during the first hours of
operation.
•
Ventilate the stove in the first performances.
•
This product must be never use as a waste incinerator.