Care And Cleaning; Troubleshooting - Glacier bay FW0AC000CP Guía De Instalación Y Cuidado

Ocultar thumbs Ver también para FW0AC000CP:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Care and Cleaning

To clean, wipe down with a damp cloth and towel dry.
Do not use abrasive cleaners, steel wool, or harsh chemicals when cleaning this faucet, or the warranty will
be voided.

Troubleshooting

NOTE: Refer to the service parts section in this manual
for a detailed drawing showing the location of the parts
listed below.
Problem
There are leaks from the
handle.
The aerator leaks or has a
reduced water flow.
The spout leaks.
The sink drain at the base of
the sink is leaking.
The water will not shut off
completely.
Possible Cause
The bonnet nut is loose.
The O-ring on the cartridge is
dirty or damaged.
The aerator is dirty or mis-fitted.
The cartridge may be clogged.
The retainer nut is loose.
The sink surface is rough or
irregular.
The locking nut is loose or
cartridge is not positioned
correctly.
Solution
Tighten the bonnet nut.
Clean or replace the O-ring.
Remove the aerator and check for
debris.
Remove the cartridge and check for
debris.
Ensure the aerator is properly
installed.
Tighten the retainer nut.
Apply additional silicone sealant to
the beveled side of the drain flange.
Retighten and test for leaks.
Remove the handle and cartridge to
check the rubber seat and spring.
Tighten the lock nut.
Clean or replace.
10

Publicidad

Capítulos

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

277-531

Tabla de contenido