200110086 120V APS MV-cabinetEn-Sp 93-2006.qxd 1/4/02 10:37 AM Page 1 Owner’s Manual APS PowerVerter ® Alternative Power Sources (120V, 60 Hz) • Voltage- and Frequency-Controlled • Peak Power • High Efficiency Introduction Important Safety Instructions Configuration & Connection Features Maintenance and Service Warranty Troubleshooting Specifications...
200110086 120V APS MV-cabinetEn-Sp 93-2006.qxd 1/4/02 10:37 AM Page 2 Introduction Congratulations! You’ve purchased the most advanced, feature-rich integrated inverter/battery charger on the market. Your APS provides your equipment with utility-supplied AC power when it is available, and during blackouts, overvoltages and brownouts, your APS automatically switches over to an external battery source to power connected equipment with voltage and frequency-controlled AC power.
Página 3
200110086 120V APS MV-cabinetEn-Sp 93-2006.qxd 1/4/02 10:37 AM Page 3 Introduction continued 3-Stage Battery Charger Your APS recharges your battery faster than Stage 2 conventional chargers because its three-stage Absorption charger profile (Bulk, Absorption and Float) are optimized, regardless of the type of battery you use (Wet or Gel).* In addition, the advanced Stage 3 charging system protects against over-charge...
200110086 120V APS MV-cabinetEn-Sp 93-2006.qxd 1/4/02 10:37 AM Page 4 Important Safety Instruction SAVE THESE INSTRUCTIONS This manual contains important instructions and warnings that should be followed during the installation, operation and storage of all Tripp Lite APS Systems. APS Location Warnings •...
200110086 120V APS MV-cabinetEn-Sp 93-2006.qxd 1/4/02 10:37 AM Page 5 Configuration Configuration Dip Switch Settings DIP SWITCH GROUP A (All models) BATTERY TYPE / VOLTAGE POINT Using a small tool, set the 4 “Battery Type / Voltage Point” Configuration DIP Switches, Group A (located on the front panel of your APS;...
Página 6
200110086 120V APS MV-cabinetEn-Sp 93-2006.qxd 1/4/02 10:37 AM Page 6 Configuration continued DIP SWITCH GROUP B (Available on Select Models) LOAD SHARING/EQUALIZE BATTERY CHARGE The “Load Sharing” Configuration DIP Switches, #1 and #2 of Group B (located on the front panel of your APS;...
Página 7
200110086 120V APS MV-cabinetEn-Sp 93-2006.qxd 1/4/02 10:38 AM Page 7 Configuration continued • Equalize Battery Charge (DIP Switch #3, Group B) This DIP Switch is momentarily engaged to begin the process of equalizing the internal resistance of your battery's cells. This can extend the useful life of certain types of batteries; consult with your battery's manufacturer to determine if your batteries could benefit from this process.
Página 8
200110086 120V APS MV-cabinetEn-Sp 93-2006.qxd 1/4/02 10:38 AM Page 8 Battery Selection Selecting Battery Type Select a battery or system of batteries that will provide your APS with proper DC voltage and an adequate amp hour capacity.* Select ‘Deep-Cycle’ batteries to enjoy optimum performance from your APS.
Página 9
200110086 120V APS MV-cabinetEn-Sp 93-2006.qxd 1/4/02 10:38 AM Page 9 Battery Connection Standard 1. Connect your APS’s positive DC Terminal directly to a fuse. UL recommends that you install a recognized UL component fuse block and fuse within 18 inches of the battery. The fuse’s rating must equal or exceed the Minimum DC Fuse Rating listed in your APS model’s specifications on pages 16 or 17.
Página 10
200110086 120V APS MV-cabinetEn-Sp 93-2006.qxd 1/4/02 10:38 AM Page 10 AC Connection Before AC connection, match the power requirements of your equipment with the power output of your APS to avoid overload. When figuring the power requirements of your equipment, do not confuse “continuous” power ratings with “peak”...
200110086 120V APS MV-cabinetEn-Sp 93-2006.qxd 1/4/02 10:38 AM Page 11 AC Connection continued Set Operating Mode Switch • Switch to “AUTO/REMOTE” when you are using connected equipment. ADVANTAGE: Uninterruptible power supply. Provides battery backup power during blackouts or brownouts. Note: When the switch is in the “AUTO/REMOTE” position, you can operate a user-supplied switch to transfer between battery-backup and charge-only modes.
Página 12
200110086 120V APS MV-cabinetEn-Sp 93-2006.qxd 1/4/02 10:38 AM Page 12 Switches, Indicator Lights & Other Features continued Indicator Lights 4. “LINE” (All models): This green light will turn continuously ON whenever connected equipment is receiving utility-supplied AC power and your APS is set to “AUTO/REMOTE”, meaning that it will provide battery backup if utility power fails.
Página 13
200110086 120V APS MV-cabinetEn-Sp 93-2006.qxd 1/4/02 10:38 AM Page 13 Switches, Indicator Lights & Other Features continued Other Features 9. DC Input Terminals (All models): The terminals’ lug screws secure the wires leading from your external battery or battery system. Your battery or battery system must provide your APS with proper DC voltage and your equipment with an adequate amp hour capacity.
200110086 120V APS MV-cabinetEn-Sp 93-2006.qxd 1/4/02 10:38 AM Page 14 Maintenance & Service Maintenance Your APS model requires no maintenance but should be kept dry at all times. Periodically check all cable connections both at the unit and at the battery. Clean and tighten connections as necessary. Service If returning your APS to Tripp Lite, please pack the APS carefully, using the ORIGINAL PACKING MATERIAL that came with the unit.
200110086 120V APS MV-cabinetEn-Sp 93-2006.qxd 1/4/02 10:38 AM Page 15 Troubleshooting Try these remedies for common APS problems before calling for help. Call Tripp Lite Customer Service at (773) 869-1234 before returning your APS for service. SYMPTOM PROBLEMS CORRECTIONS APS does not provide APS not properly connected to Connect APS to utility power.
200110086 120V APS MV-cabinetEn-Sp 93-2006.qxd 1/4/02 10:38 AM Page 16 Specifications (Corded Models) CORDED MODELS: APS 1012 Weight: 26.4 lbs. INVERTER Continuous power (@ 20° C): 1000 W Surge power (5 seconds): 2000 W Efficiency (Full Load): Minimum DC Fuse Rating: 225A DC Input Current @ Nominal V DC Full Load...
Página 17
200110086 120V APS MV-cabinetEn-Sp 93-2006.qxd 1/4/02 10:38 AM Page 17 Specifications (Hardwired Models) HARDWIRED MODELS: APS 1524 APS 2012 Weight: 26.4 lbs. 38.0 lbs. INVERTER Continuous power (@ 20° C): 1500 W 2000 W Surge power (5 seconds): 3000 W 4000 W Efficiency (Full Load): Minimum DC Fuse Rating:...
200110086 120V APS MV-cabinetEn-Sp 93-2006.qxd 1/4/02 10:38 AM Page 19 Introducción Introducción ¡Felicitaciones! Usted ha adquirido el inversor / cargador de batería integrado más avanzado y con más características en el mercado. Este modelo APS suministrará a sus equipos energía de CA mientras ésta esté...
Página 20
200110086 120V APS MV-cabinetEn-Sp 93-2006.qxd 1/4/02 10:38 AM Page 20 Introducción continua Cargador Avanzado de 3 Etapas para Baterías Este sistema APS recargará sus baterías más Stage 2 Absorption rápido que otros cargadores convencionales debido a que su perfil de recarga de 3 etapas (Alimentación Masa, Absorción...
200110086 120V APS MV-cabinetEn-Sp 93-2006.qxd 1/4/02 10:38 AM Page 21 Seguridad Este manual contiene advertencias e instrucciones importantes que deben seguirse durante la instalación, operación y almacenaje de todos los Sistemas APS de Tripp Lite. Precauciones Sobre la Ubicación del APS •...
200110086 120V APS MV-cabinetEn-Sp 93-2006.qxd 1/4/02 10:38 AM Page 22 Configuración Regulación de los Interruptores DIP de Configuración GRUPO A DE INTERRUPTORES DIP (Todos los modelos) TIPO DE BATERÍAS / PUNTOS DE VOLTAJA Usando una herramienta pequeña, ajuste los 4 Interruptores DIP de Configuración, Grupo A: “Battery Type / Voltage Point”...
Página 23
200110086 120V APS MV-cabinetEn-Sp 93-2006.qxd 1/4/02 10:38 AM Page 23 Configuración continua GRUPO B DE INTERRUPTORES DIP (Modelos Selectos) COMPARTICION DE CARGA / IGUALAR CARGA DE BATERIAS Usando una herramienta pequeña, ajuste los Interruptores DIP de Configuración “Load Sharing” (compartición de carga) del Grupo B (ubicados en el panel frontal del sistema APS; vea el Diagrama 1, página 36).
Página 24
200110086 120V APS MV-cabinetEn-Sp 93-2006.qxd 1/4/02 10:38 AM Page 24 Configuración continua • Igualar la Carga de Baterías (Interruptores DIP No. 3, Grupo B) Este interruptor DIP se acciona momentáneamente para iniciar el proceso de igualar la resistencia interna de las pilas. Con ello se prolonga la vida útil de algunos tipos de pilas; consulte con el fabricante de sus pilas para conocer si éstas se beneficiarían con dicho proceso.
Página 25
200110086 120V APS MV-cabinetEn-Sp 93-2006.qxd 1/4/02 10:38 AM Page 25 Selección de Baterías Seleccione el Tipo de Batería(s) Seleccione una batería o sistema de baterías que suministre voltaje apropiado de CD y capacidad adecuada en amperios / hora al sistema APS.* Seleccione baterías de ciclo profundo para obtener el máximo rendimiento de su sistema APS.
Página 26
200110086 120V APS MV-cabinetEn-Sp 93-2006.qxd 1/4/02 10:38 AM Page 26 Montaje (Opcional*) (Refiérase al diagrama 2, página 36) El usuario debe suministrar todos los sujetadores y piezas de fijación necesarias y verificar que éstas sean adecuadas para la superficie de montaje que desea utilizar. Apague el PowerVerter y todos lo equipos conectados antes de comenzar el proceso de montaje.
Página 27
200110086 120V APS MV-cabinetEn-Sp 93-2006.qxd 1/4/02 10:38 AM Page 27 Conexión de Baterías continua Los cables de conexión de las baterías deben ser de longitud mínima posible y en ninguna circunstancia deben exceder 10 pies de longitud. Los cables cortos y de calibres espesos limitan la pérdida de voltaje de CD y permite transferencia máxima de corriente.* Debe apretar las terminales o bornes de las baterías a una torsión de aproximadamente 4 Newton-metro para crear una conexión eficiente y prevenir sobrecalentamiento excesivo.
Página 28
200110086 120V APS MV-cabinetEn-Sp 93-2006.qxd 1/4/02 10:38 AM Page 28 Conexión de CA Antes de la conexión de CA, cerciórese de que la demanda de energía de sus equipos coincida con la capacidad de salida del APS para evitar sobrecargas. Cuando calcule la demanda de energía de sus equipos, no confunda el índice de energía “continua”...
200110086 120V APS MV-cabinetEn-Sp 93-2006.qxd 1/4/02 10:38 AM Page 29 Conexión de CA continua Conexión de la Salida Eléctrica de CA (Todos los modelos con cable) Simplemente conecte sus equipos a los receptáculos de CA de la unidad. Regule el Interruptor “Operating Mode” (Modo de Operación) •...
Página 30
200110086 120V APS MV-cabinetEn-Sp 93-2006.qxd 1/4/02 10:38 AM Page 30 Interruptores, Luces Indicadoras y Otras Características continua Luces Indicadoras 4. “LINE” (Línea – Todos los modelos): Esta luz verde se iluminará continuamente para indicar que los equipos conectados están recibiendo energía de CA suministrada por la compañía local de electricidad y el sistema APS está...
Página 31
200110086 120V APS MV-cabinetEn-Sp 93-2006.qxd 1/4/02 10:38 AM Page 31 Interruptores, Luces Indicadoras y Otras Características continua Otras Características 9. Terminales de Entrada de CD (Todos los modelos): Las tuercas aseguran los cables provenientes de la batería externa o sistema externo de baterías. Sus baterías o sistema de baterías deben proporcionar voltaje adecuado de CD al sistema APS y a sus equipos, y también capacidad adecuada en amperios/hora.
200110086 120V APS MV-cabinetEn-Sp 93-2006.qxd 1/4/02 10:38 AM Page 32 Mantenimiento y Servicio Mantenimiento Este sistema APS no requiere mantenimiento alguno. No obstante, debe mantenerse seco en todo momento. Verifique periódicamente todas las conexiones y cables en la unidad y sus baterías. Apriete y limpie estas conexiones como sea necesario.
200110086 120V APS MV-cabinetEn-Sp 93-2006.qxd 1/4/02 10:38 AM Page 33 Resolucion de Problemas Si experimenta problemas comunes refiérase a esta guía antes de llamar al centro de servicios. Llame al Servicios a Clientes de Tripp Lite antes de enviar el sistema APS. SIMTOMA PROBLEMAS SOLUCION...
200110086 120V APS MV-cabinetEn-Sp 93-2006.qxd 1/4/02 10:38 AM Page 34 Especificaciones (Modelos con cable) MODELOS CON CABLE: APS1012 Peso: 11.9 Kg 11.9 Kg INVERSOR Energía continua a 20º C 1000 Vatios Energía de sobretensiones transitorias (5 segundos): 2000 Vatios Eficiencia (Carga Completa): Indice Mínimo de Capacidad del Fusible: 225A Corriente de Entrada de CD a Niveles Nominales...
Página 35
200110086 120V APS MV-cabinetEn-Sp 93-2006.qxd 1/4/02 10:38 AM Page 35 Especificaciones (Modelos con toma directa al circuito) MODELOS CON TOMA DIRECTA AL CIRCUITO: APS1524 APS2012 Peso: 12.0 Kg 17.1 Kg INVERSOR Energía continua a 20º C 1500 Vatios 2000 Vatios Energía de sobretensiones transitorias (5 segundos): 3000 Vatios 4000 Vatios...
Página 36
200110086 120V APS MV-cabinetEn-Sp 93-2006.qxd 1/4/02 10:38 AM Page 36 Diagrams/Esquemas See “Configuration”, pg. 5. 1.1 is DIP Switch Group A. 1.2 is DIP Switch Group B. Refiérase a la sección “Configuración”, página 22. 1.1 representa el Grupo A de Interruptores DIP. 1.2 representa el Grupo B de Interruptores DIP OUTPUT/NEUTRA OUTPUT/HOT...
Página 37
200110086 120V APS MV-cabinetEn-Sp 93-2006.qxd 1/4/02 10:38 AM Page 37 Diagrams/Esquemas X Volts See Battery Connection, Pg. 9. 4.1 is the fuse. X = Your APS’s Inverter's Nominal Input Voltage. (See specs.) Refiérase a la sección “Conexión de Baterías”, página 26. 4.1 representa el fusible. X = El Voltaje Nominal de Entrada del Inversor del APS.
Página 38
200110086 120V APS MV-cabinetEn-Sp 93-2006.qxd 1/4/02 10:38 AM Page 38 Diagrams/Esquemas Basic 12VDC Vehicular Battery Connection. See Pg. 9. 7.1 is the alternator. 7.2 is the vehicle battery ground. 7.3 is the vehicle battery. 7.4 is the fuse. Conexión Básica de Baterías de 12V de CD en Vehículos. Vea página 27. 7.1 representa el alternador.
Página 39
200110086 120V APS MV-cabinetEn-Sp 93-2006.qxd 1/4/02 10:38 AM Page 39 Diagrams/Esquemas Corded Model • Modelo con Cable 1. Operating Mode Switch (All models) 1. Interruptor “Operating Mode” (Modo de operación) 2. DIP Switch Group A (All models) 2. Grupo A de Interruptores DIP 3.
Página 40
200110086 120V APS MV-cabinetEn-Sp 93-2006.qxd 1/4/02 10:38 AM Page 40 Diagrams/Esquemas Hardwired Model • Modelo con Toma Directa al Circuito OUTPUT/NEUTRA OUTPUT/HOT GROUND INPUT/NEUTRA INPUT/HOT “FOR USE WITH COPPER WIRE ONLY” 1. Operating Mode Switch (All models) 1. Interruptor “Operating Mode” (Modo de operación) (Todos los modelos) 2.