-Floor-standing single-hole tub filler with single lever handle
-Includes 2-way diverter & hand-held shower head with 59" flexible hose
-Brass construction with pressure balancing ceramic disc cartridge
-Includes rough-in and trim
-Flow rate: 7.2 GPM at 60 PSI
-It can be installed to meet ADA compliance
Important: Keep this manual for future technical assistance and/or replacement parts. Please read the instructions within
the booklet carefully prior to installation. LACAVA recommends that this fixture be installed by a professional plumber and
will not be held responsible for any damage caused by improper installation. It is the responsibility of the homeowner to
ensure that this fixture complies with all local plumbing codes. Shut off water supply before starting installation. Please see
the Terms & Conditions found within this booklet for additional information. For technical assistance please contact
888-522-2823 (toll free).
Importante: Guarde este manual para futura asistencia técnica y / o piezas de repuesto. Por favor, lea las instrucciones
en el folleto cuidadosamente antes de la instalación. LACAVA recomienda que este aparato sea instalado por un técnico
y no se hace responsable de los daños causados por una instalación incorrecta. Es la responsabilidad del propietario
garantizar que este aparato cumpla con todos los códigos de plomería locales. Por favor, consulte nuestros Términos y
Condiciones que se encuentran en este folleto para información adicional. Para obtener asistencia técnica, por favor
contacte a: 888-522-2823 (llamada gratuita).
Table of Contents/Contenido:
Page 2: Product Specifications/Especificaciones de Producto
Page 3: Parts Breakdown/Desglosamiento de Partes
Page 4, 5, 6: Installation Instructions/Instrucciones de Instalación
Page 7: Cleaning & Care/Cuidado y Limpieza
Page 8: Warranty/Garantía
Page 9, 10: Terms and Conditions/Términos y Condiciones
6630 west wrightwood ave chicago il 60707 usa tel 773 637 9600 fax 773 637 9601 info@lacava.com www.lacava.com

Publicidad

loading

Resumen de contenidos para Lacava 1595

  • Página 1 Important: Keep this manual for future technical assistance and/or replacement parts. Please read the instructions within the booklet carefully prior to installation. LACAVA recommends that this fixture be installed by a professional plumber and will not be held responsible for any damage caused by improper installation. It is the responsibility of the homeowner to ensure that this fixture complies with all local plumbing codes.
  • Página 2 1/16. Nota: Los planos proporcionados en este documento tienen el propósito de dar al usuario una idea del producto y no están hechos a escala. Los tamaños de pulgadas se redondean al más cercano 1 / 16. LACAVA LLC...
  • Página 3 Parts: R046 - Replacement ceramic cartridge 1560 - Hand-held shower head A00045 - 59” flexible shower hose 1595-AERATOR - Replacement aerator cartridge Note: Please reference this sheet and the corresponding part number when requesting parts. Nota: Por favor referirse a esta pagina y la parte correspondiente cuando ordene partes.
  • Página 4 7. Ensure the plug is still tightly installed onto the top of the brass body and turn on the water supply. Check for leaks and repair if necessary. 8. Turn water supply off. LACAVA LLC...
  • Página 5 3” 10. Remove the plug from the rough-in assembly. 11. Check that the o-rings are intact at the end of each internal supply line and then add lubricant so that the o-rings do not tear when installed. LACAVA LLC...
  • Página 6 20. Reinstall the aerator assembly onto the spout. 21. Attach the open end of the shower hose to the hand- held shower head and rest the shower head onto its hook. 22. Place a bead of silicone around the escutcheon to create a watertight seal. LACAVA LLC...
  • Página 7 - Nunca use materiales abrasivos o productos de limpieza que contienen amoníaco, lejía o ácido, ya que pueden causar daños a la superficie acabada. ¡Nos gustaría darle las gracias por su compra y estamos seguros que usted podrá disfrutar de nuestros productos por muchos años! LACAVA LLC...
  • Página 8 If a defect is found under normal use, while under warranty, LACAVA will repair or replace the product (whichever cost is smaller to LACAVA) at its own expense (excluding shipping and installation charges).
  • Página 9 RETURN POLICIES: If the product is not satisfactory for any reason different from defects, it can be returned to LACAVA LLC up to 30 days from the shipping date after obtaining a Return Goods Authorization (RGA) valid for 60 days. If the product is not returned to LACAVA within that timeframe, the RGA will be voided and no further RGAs will be issued for the product.
  • Página 10 Autorización de Devolución de Bienes (RGA), válida por 60 días. Si el producto no se devuelve a LACAVA dentro de ese plazo, la RGA se anularán y no se RGA se emitirán nuevos para el producto.