PLACINGTHEMACHINEINSERVICE
Always use of an air line lubricator with these machine. We recommended the
following Filter-Lubricator-Regulator Unit: FACOMN.580.
Every eight hours' operation, if a lubricator is not used on the compressed air
network, inject 1/2 to 1cm
through the machine's inlet connection.
3
Model
Pad
mm
V.410F
Ø 178
Model
Free speed
rpm
V.410F
4200
* k = measurement uncertainty in dB
WE, FACOM S.A.S., 6/8 RUE GUSTAVE EIFFEL - BP 99 - 91 423 MORANGIS CEDEX FRANCE, DECLARE UNDER OUR OWN RESPONSIBILITY THAT THE
PRODUCT V.410F–FACOMØ178MMAIRVERTICALDISCSANDER
- IS IN CONFORMITY WITH THE «MACHINERY»DIRECTIVE2006/42/CE
- AND IS IN CONFORMITY WITH THE PROVISIONS OF THE HARMONISED EUROPEAN STANDARD EN ISO11148-8:2011
EN ISO 12100:2010
EN ISO 15744:2008
EN ISO 28927-3:2009
LUBRIFICATION
1
3
Pressure dB(A)
k*
87,4
3
Air consumption
l/min
130
** k = measurement uncertainty in m/s²
CEDECLARATIONOFCONFORMITY
4
Noise level
Power dB(A)
Pressure dB(C)
k*
98,4
3
90,8
Working
Weight
pressure
bar
kg
6,2
2,6
EMERGENCY
GATE VALVE
2
Vibrations level
m/s
k*
3
< 2,5
Dimensions
mm
250 x 260 x 190
F
ACOM QUALITY MANAGER
2
k**
0,69
20.01.2010