The LED indicator in the detector tip (1) signals the following:
Green LED: Tester ready / off-circuit area
Red LED with alarm: Live wires in vicinity
LED off: Tester not ready
4
Localising electrical voltages
Fig. G: Position the detector tip in the area to be tested (e.g. cable, socket. etc.).
Fig. H: When voltage is present, the detector tip lights red and a signal sounds.
!
For safety, check all three phase conductors (L1, L2, L3) for the presence
of voltage!
!
Change the batteries when the acoustic signal is weak.
Please be aware that even if a visual signal is not displayed, voltage may
!
still be present. Differences in the design of the connection socket or
the nature of the insulation (thickness and type) can affect functionality.
Voltage cannot be detected behind panels and metal covers.
Information on maintenance and care
Clean all components with a damp cloth and do not use cleaning agents,
scouring agents and solvents. Remove the battery(ies) before storing for
longer periods. Store the device in a clean and dry place.
Technical data
Indicator
Voltage range
Overvoltage category
Power supply
Operating conditions
Storage conditions
Dimensions (W x H x D)
Weight (incl. batteries)
EU directives and disposal
This device complies with all necessary standards for the free movement of
goods within the EU. This product is an electric device and must be collected
separately for disposal according to the European Directive on waste electrical
and electronic equipment. Further safety and supplementary notices at:
http://laserliner.com/info?an=acfion
Subject to technical alterations. Rev18W41
LED (red/green)
50 V AC ~ 1000 V AC
Frequency 50 ... 60 Hz
CAT III - 1000 V (non-condensing)
Pollution degree 2
2 x 1.5 AAA (NEDA 24A/IEC LR 03)
0°C ... 50°C, Max. humidity 80% rH,
no condensation,
max. altitude 2000 m
-10°C ... 60°C,
Max. humidity 80% rH
19 x 139 x 25 mm
48 g
(see Fig. K)