Troubleshooting - Hamilton Beach SodaStation Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Troubleshooting

PROBLEM
No carbonation.
Slight carbonation.
Too carbonated.
Bottle is locked after
carbonation.
Carbonating unit door will
not open.
840238400 ENv02.indd 7
840238400 ENv02.indd 7
PROBABLE CAUSE/SOLUTION
• Check if CO
cartridge has been used. Use a brand new cartridge.
2
• Cartridge is too cold. Wait until cartridge reaches room temperature.
• Water is too warm. Use 33° to 42°F (0.5° to 5.5°C) filtered or bottled water.
• Carbonating unit allowed to remain on bottle too long after charging. Press the pressure release button.
Remove promptly after charging in the future.
• Clogged nozzle. Press the pressure release button. DO NOT attempt to remove the carbonating unit
from the bottle. Contact Hamilton Beach for repair or replacement.
• Fill water to appropriate fill level. Do not fill above MAX Fill Level for soda.
• CO
is not mixed well with water. Allow 10 seconds after CO
2
• Use very cold (33° to 42°F [0.5° to 5.5°C]) refrigerated water.
• Shake well after carbonating.
• Carbonation adjustment dial is not set in the correct position. Adjust carbonation adjustment dial
counterclockwise.
• Too little water. Fill water to bottle markings up to MAX Fill Level.
• This is normal. Release pressure by pushing on pressure release button on top of carbonating unit.
• Pressure was not released. Press the pressure release button to relieve pressure; then rotate CO
knob counterclockwise to unlock the cartridge safety lock. Lightly press door to open.
is released into water to complete mixing.
2
release
2
7
11/22/13 11:58 AM
11/22/13 11:58 AM