The tables below describe the individual functions available in the control unit.
MENU
Automatic closing time. Active only with logic "TCA"=ON.
TCA
At the end of the set time the control unit orders a closing manoeuvre.
Operating time, motor 1. The operating time is adjusted at normal speed
during motor 1 opening and closing phases. See Paragraph "Adjustment of
the gate leaf speed".
TM1
By setting the value to 0, the operation is performed with around 2 seconds
of pick-up and then the movement is carried on at reduced speed for the
entire stroke.
Operating time, motor 2. The operating time is adjusted at normal speed
during motor 2 opening and closing phases. See Paragraph "Adjustment of
the gate leaf speed".
TM2
By setting the value to 0, the operation is performed with around 2 seconds
of pick-up and then the movement is carried on at reduced speed for the
entire stroke.
The opening percentage of motor 1 (pedestrian function) is adjusted.
If the logics NOLS=ON, the opening percentage will always be 100%, in spite
TPED
of the preset value.
If TM1<5 sec., the opening percentage will always be 100%, in spite of the
preset value.
Duration of braking. Preset a value which must be higher than the braking.
TSLD
See section "Adjustment of speed"
The anti-crash device* (amperometric sensor) operation is adjusted in the
PMo1
opening phase, at normal speed - Motor 1.
The anti-crash device* (amperometric sensor) operation is adjusted in the
PMC1
closing phase, at normal speed - Motor 1.
The anti-crash device* (amperometric sensor) operation is adjusted in the
PMo2
opening phase, at normal speed - Motor 2.
The anti-crash device* (amperometric sensor) operation is adjusted in the
PMc2
closing phase, at normal speed - Motor 2.
Mot.2 opening delay time.
TDMo
Regulates the delay time of motor 2 on opening with respect to motor 1
Mot.1 closing delay time
TDMC
Regulates the delay time of motor 1 on closing with respect to motor 2
TLOc
Electric lock activation time. The value is expressed in 1/10s (0=0s - 50=5s)
Motor speed during braking is adjusted. Values are expressed in percentage
SLDs
with respect to normal operating speed.
The anti-crash device* (amperometric sensor) operation is adjusted in the
Pso1
opening phase, at reduced speed - Motor 1.
The anti-crash device* (amperometric sensor) operation is adjusted in the
Psc1
closing phase, at reduced speed - Motor 1.
The anti-crash device* (amperometric sensor) operation is adjusted in the
Pso2
opening phase, at reduced speed - Motor 2.
The anti-crash device* (amperometric sensor) operation is adjusted in the
Psc2
closing phase, at reduced speed - Motor 2.
* WARNING: AN INCORRECT SETTING OF THESE PARAMETERS MAY RESULT IN AN HAZARD.
COMPLY WITH REGULATIONS IN FORCE!
** 1: maximum sensitivity - 99:minimum sensitivity.
PARAMETERS, LOGIC AND SPECIAL FUNCTIONS
FUNCTION
MEMO
MIN-MAX-(Default)
1-240-(40s)
0-180-(5s)
0-180-(5s)
25-50-75-100
(50%)
1-30-(15s)
1-99-(50%)**
1-99-(50%)**
1-99-(50%)**
1-99-(50%)**
0-15-(2s)
0-40-(3s)
0-50 (5=0,5s)
20-99 (50)
1-99-(50%)**
1-99-(50%)**
1-99-(50%)**
1-99-(50%)**