CAUTION
Risk of injury and damage! Note the weight
of the appliance in case of storage.
This appliance must only be stored in inte-
rior rooms.

Care and maintenance

DANGER
First pull out the plug from the mains before
carrying out any tasks on the machine.
Exchanging the flat pleated filter
 Open filter door.
 Replace the flat pleated filter.
 Close the filter door, it must lock into
place.
Cleaning the electrodes
 Release and remove the suction head.
 Clean the electrodes with a brush.
 Insert and lock the suction head.

Troubleshooting

DANGER
First pull out the plug from the mains before
carrying out any tasks on the machine.
Suction turbine does not run
 Check the receptacle and the fuse of
the power supply.
 Check the power cable, the power plug
and electrodes of the device.
 Turn on the appliance.
Suction turbine turns off
 Empty the container.
Suction turbine does not start again
after the container has been
 Turn off the appliance and wait for 5
seconds, turn it on again after 5 sec-
onds.
 Clean the electrodes as well as the
space between the electrodes with a
brush.
10

Storage

emptied
Suction capacity decreases
 Remove blockages in the suction noz-
zle, suction tube, suction hose, or flat
pleated filter.
 Replace fleece filter bag.
 Ensure the filter cover properly locks
into place.
 Clean or replace the membrane filter
(special accessory) under running wa-
ter.
 Replace the flat pleated filter.
Dust comes out while vacuuming
Illustration
 Check/correct the correct positioning of
the flat fold filter.
 Replace the flat pleated filter.
Automatic shut-off (wet vacuum
cleaning) does not react
 Clean the electrodes as well as the
space between the electrodes with a
brush.
 Continuously check the filling level in
case of non-conductive liquid.
Automatic filter cleaning is not
 Suction hose is not connected.
Automatic filter cleaning cannot be
 Inform Customer Service
Automatic filter cleaning cannot be
 Inform Customer Service
Customer Service
If malfunction can not be fixed, the de-
vice must be checked by customer ser-
vice.
– 4
EN
working
switched off
switched on