Troubleshooting - Astralpool VICTORIA PLUS SILENT VS Manual De Instrucciones

Ocultar thumbs Ver también para VICTORIA PLUS SILENT VS:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 23

7. TROUBLESHOOTING

The pump is not primed
1.
The pump only releases a small flow of water
2.
The pump makes a noise
3.
1 2 3 4 5 6
Air entering the suction pipe
Filter cap badly sealed
Motor turning in wrong direction
Wrong voltage
Pre-filter blocked
Load loss in the installation
Pump incorrectly secured
Motor blocked
Increased temperature in the terminal box
due to electric arc
The thermal protection trips
Incorrect junction box connections
Installation and general maintenance manual
CAUSES
- POOL PUMPS
The pump will not start
4.
The motor is making a noise but will not start
5.
The motor has stopped
6.
SOLUTIONS
Check the condition of connections and
seals on the suction pipe
Clean the filter cap and check the condition
of the rubber seal
Invert 2 power phases
Check the voltage on the rating plate and
that of the mains
Clean the filter
Prevent parts from causing load loss
wherever possible
Secure the pump correctly
Remove the motor and contact the
technical service
Check the junction box connections
Connect the cables correctly to the junction
boxes
Tighten the cable correctly to the
junction box / Adapt the size of the cable
connection to the junction box
11

Publicidad

Tabla de contenido
loading

Tabla de contenido