insTaLLaTiOn insTRUCTiOns
Water Supply
Recommended
Maximum
Hot Water Temperature
65 C° (~150F)
80 C° (~175F)
Working Pressure
3 BAR (~45PSI)
5 BAR (~75PSI)
In case of pressures over 5 BAR (~75 PSI), we
Warning!, Do not force the screw (3.D).
recommend to use a pressure reducer.
Excessive tightening can affect the correct
Before proceeding with the assembly, purge the
function of the system or damage it. The
hot and cold water pipes so as to avoid the
thermostatic cartridge is equipped with a safety
accumulation of dirt and impurities that could
anti-scalding retainer set at 100°F (38°C). For
affect the function of the faucet.
higher temperatures push the button on the
adjustment handle. In case of hot or cold water
FiG. 01
pressure failure, the flow will automatically stop.
Remove with a screwdriver the protection covers
With a screwdriver loosen the stop cocks (3.H)
(1.A). Use the plug (1.B) if necessary.
in anti-clockwise direction.
FiG. 02
FiG. 04
Fit the faucet body to the wall with the shower
Remove the protection tape of the adhesive
outlet pointing upwards, connect the hot water
sponge (4.D) and apply it on the back of the
supply to the left inlet and the cold water supply
plate (4.C). Fit the sliding flat washers (4.B) and
to the right one.
(4.A) on the plate (4.C) and install it on the
The depth of the wall niche must correspond
thermostatic body till it is flush to the wall.
(wall coating included) to the tolerance given
by the MIN/MAX references given on the
FiG. 05
plastic cover (2.A).
For the upper portion with the stop cock, follow
Once all connections have been carried out,
the instructions given below:
activate the faucet at the working pressure
Fit the insert (5.L) on the screw down bar so as
(we recommend maintaining the water flow
to obtain the correct alignment once the handle
for a few minutes so as to purge the system
(5.F) is installed, then lock it using the included
from any debris and/or dirt inside the piping).
screw (5.I). Position the handle (5.F) and tighten
Temporarily remove the protection cover (2.A)
the grub screw (5.G). Complete the operation
to check if there are leakages and if the system
by fitting the cap (5.H).
works regularly, reinstall the protection cover
For the lower portion with the thermostatic
(2.A) and finish the external wall surface.
cartridge, follow the instructions given below:
fasten the peg (5.E) on the thermostatic cartridge
FiG. 03
bar and install the handle (5.A) putting the ring
Remove the protection cover (2.A) as shown
(5.D) in between without moving the bar so as
in FIG. 02. With a screwdriver turn the stop
to not compromise the cartridge calibration.
cocks (3.H) clockwise, loosen the fitting screw
Tighten the grub screw (5.B) and place the
(3.D) using the proper wrench and pull out the
finishing cap (5.C).
test plug (3.E). Insert the o-ring (3.C) and the
sleeve (3.B) on the thermostatic body. Fit the
FiG. 06
o-ring (3.G) into the housing on the faucet body
To replace only the handle (6.A) follow the
and assemble the protection cylinder (3.F). Use
instructions given below:
a small quantity of the special grease included
Remove the cap (6.C), loosen the grub screw
to lightly lubricate the o-rings of the thermostatic
(6.B) and pull out the handle (6.A).
cartridge (3.A). Insert the cartridge in the faucet
Install the new handle (6.A) and fasten it using
housing carefully aligning the positioning hole
the grub screw (6.B), complete by inserting the
with the housing of the fitting screw (3.D), then
cap (6.C).
tighten the latter.
Istruz. art. 8569000.indd 4-6
FiG. 01
Minimum
15 C° (~60F)
0.5 BAR (~7PSI)
FiG. 03
FiG. 02
FiG. 04
FiG. 05
FiG. 06
FiG. 07
FiG. 08
26/04/11 10:43

Publicidad

loading