SAFETY MESSAGES
Disregard of the safety messages may lead to danger of life, burning or
fire!
Installation, mounting or works on the electrical connection may only be
carried out by an approved electrician.
The product may not be modified or converted.
Do not hang or fasten anything on the product, especially no decoration.
Do not cover the product - provide free air circulation.
In case of a malfunction you may NOT touch the product or operate it
further. Disconnect the product from the power supply by an external
switch or by the fuse.
A malfunction exists when:
visible damages appear.
the product does not work properly (e.g. flickering).
smoke, steam or crackling sounds appear.
smell of burning is recognisable.
an overheating is recognisable (e.g. by discolouration of adjacent
surfaces).
Operate the product only after maintenance and examination by an
approved electrician!
This product is not intended to be used by children. Ensure that children do
not suffer any harm e.g. by burns from hot surfaces or by electrical shock.
Additional safety messages are indicated by this symbol:
USE AS DIRECTED
This product serves exclusively lighting purposes and may:
only be used with a voltage of 100-240V~50/60Hz.
only be installed according to safety class II (two).
only be operated when firmly mounted on a stable, even and tilt-fixed
surface.
only be operated on normally or not flammable surfaces.
only be used in dry condition,
not in damp or dirt-endangered rooms.
not in areas of high air humidity.
not be exposed to strong mechanical loads or to strong contamination.
MAINTANANCE AND CARE
Light source
Under regular usage the LED light source has an extraordinary long
lifetime. If nevertheless damage or failure occurs, contact your local dealer
to exchange the LED light source.
Care
Disconnect the product from the power supply and let it cool down, before
you clean the product.
Clean the product on a regular basis using a slightly moistened, soft and
fluff-free cloth. Please also note additional supplied notes on maintanance
and care.
STORAGE AND DISPOSAL
Storage
The product must be stored in a dry and clean environment. Do not strain
the product mechanically during storage.
After a damp or soiling storage the product may only be installed after
checking its condition by an approved electrician.
Disposal (European Union)
Do not dispose the product with the regular household waste! Products
marked with this sign must be disposed according to the directive(WEEE,
2003/108) on electrical and electronic devices at local collection points for
such devices!
INSTALLATION
(only by an approved electrician)
Switch off the mains or respectively the connection lead before doing any
works!
Keep the whole installation off power until the work is completely finished. A
connection with the power on will destroy the LED!
Use only parts, which are supplied with the product or are described as
accessories!
Inspect the product for loose parts inside the housing. When there are loose
parts inside the housing and these are not explicitly described the product may
not be installed or operated.
Use the supplied fastening material only when it is suited for the installation
background. If this is not the case use only fastening material suiting the
installation background.
Unpacking
Carefully take the product out of the packaging removing any transport
safeguards.
.
Before disposal of the packaging material make sure that all components of
the product are removed.
Installation place
The product is solely suited for recessed wall- and ceiling installation.
LED react sensitive on high temperatures! Before installation pay attention to
the expected temperature at the place of operation. This may not exceed the
allowed ambient temperature (ta=$ta$°C) of the product.
Note the minimum distances in the ceiling. Minimum distance to each side: 5
cm.
Keep a sufficient distance to flammable surfaces. The indicated recess
depth is the minimum depth. Depending on the installation situation the needed
recess depth may be larger. This is especially the case, when there are
flammable materials above the luminaire or to ensure the sufficient ventilation
Do not cover the product, especially not with insulating materials:
Installation steps (read completely before installation)
Install the luminaire as shown in the figure.
Mark and cut the opening. Do not damage the mains lead. The
measurements for the openings are:
Ø: 160571 cm
Electrical Connection
For electric connection attach the black or brown wire (live conductor)
and the blue wire (neutral conductor) of the mains supply with the 230V
(PRI ~) clamp of the transformer.
Secure the connection cord with the strain relief.
Direct the luminaire into the opening, with the retaining springs pointing
upwards.
Check if the product functions properly and is securely fixed!
art.-no. 160571 © 19.07.2013 SLV Elektronik GmbH, Daimlerstr. 21-23, 52531
Übach-Palenberg, Germany, Tel. +49 (0)2451 4833-0
Technical Details are subject to change.
.
.