INSTALLATION INSTRUCTIONS (CONTINUED)
Lubrication
This unit contains no oil.
Before operating compressor, fill to
the center of the sight gauge (see Figure 10).
Using any other type of oil may
shorten pump life and damage
valves.

Quick Reference

Recommended Oil (2 Options)
Single viscosity SAE 30 ISO100 nondetergent
compressor oil. Part number 1WG50 or 4ZF21.
10W30 synthetic oil such as Mobil 1
Oil Capacity
Approximately 2 quarts
Fill the pump with oil to the center of the sight gauge
using oil fill opening (see Figure 10).
pump through the breather cap opening as this may
cause oil to leak and spray out during operation.
NOTE: Some residual oil may still be in the pump from
factory testing leaving a thin coat on the sight gauge;
however, there is not enough oil to operate the unit.
OPERATING INSTRUCTIONS
IMPORTANT: Check motor rotation before operating the
compressor.
All lubricated compressor pumps discharge some condensed
water and oil with the compressed air. Install appropriate
water/oil removal equipment and controls as necessary for
the intended application.
Failure to install appropriate
water/oil removal equipment may
result in damage to machinery or workpiece.
Guarding
The belt guard provided must
be installed before operating the unit.
All moving parts must be guarded. All electrical covers must be
installed before turning on the power.
12
or 1WG49.
®
Do NOT fill the
Figure 10 - Lubrication
Oil Fill Plug
Oil Drain Plug