F
EATURES OF THE
Polished chrome finish draft
arms with faucet and
connecting lines and
stainless steel beer drip pan
Door locks furnished
standard
Strong body with thick walls,
injected with CFC-free
polyurethane foam
Exterior cabinet made of
galvanized, pre-painted
steel, with baked polyester
paint
Interior lining made of
acrylic-coated galvanized
steel for extra corrosion
resistance
Heavy-duty R-134a
condensing unit with easy
access for maintenance
R
S
EFRIGERATION
Description of its components
Compressor:
The compressor is a factory-sealed unit located underneath (outside) the cooling cabinet. This pump is
activated by a motor which draws low-pressure vapor (refrigerant) from the evaporator. It then
compresses the gas and forces it into the condenser at a high pressure.
Starter relay:
The starter relay is attached on one side of the compressor box. The compressor motor has two
windings: one for starting and another for running. In order to provide for necessary additional torque
when the motor is first ignited, the starter relay connects the additional start-up windings. After the motor
reaches its correct operating speed, the relay opens the ignition windings and the motor carries on with
the operation windings.
Thermal protector:
This protector is a thermo-sensible device attached to one side of the compressor's box. In any given
situation, if the compressor overheats or the voltage source varies drastically, the thermal protector
opens, turning off the compressor. After the compressor cools down to a normal and safe working
temperature, the thermal protector turns on the compressor.
© 2004, IMI Cornelius Inc.
ENGLISH
U
NIT
FIGURE 1
YSTEM
- 1 -
COR15DBD2DT Service Manual
Sturdy, stainless steel top
Forced-air evaporator for
quick temperature pull-
down
Reinforced, 16 gauge
galvanized steel base
Forced-air condenser made
of copper and aluminum,
resistant to rust and saline
environments
Publication Number: 630460275SER