5. Tighten the fi tting by hand until it is snug, then make two-thirds of a
turn with a wrench.
CAUTION
6. Turn on the HOT and COLD water supplies and check all the water supply intake
connections and the faucets for water leaks.
Connecting the drain hose
Drain can be installed using method you need.
1. fl oor standpipe
-
-
-
-
2. laundry tub.
-
-
-
3. Over the edge of a wash basin
-
Make sure that the connection between the drain hose
and the standpipe is not airtight.
WA484DSHA-03050D-01_EN.indd Sec3:17
WA484DSHA-03050D-01_EN.indd Sec3:17
To ensure the correct water usage, connect both the HOT and
COLD water faucets. If either or both are not connected, an
"nF" (no fi ll) error can occur.
Check if the water supply hose is not twisted or bent. If the
hose is twisted or bent, there is a danger of a water leakage and
electric shock due to the water leakage.
Minimum diameter for a standpipe drain: 2" (51 mm).
Minimum carry-away capacity: 17 gal. (64 Liter) per
minute.
Top of standpipe must be at least 39" (990 mm) high, install
no higher than 96" (2.4 m) from bottom of washer.
If you must install higher than 96" (2.4 m), you will need a
sump pump system.
Minimum capacity: 20 gal. (76 Liter).
Top of laundry tub must be at least 39" (990 mm) above fl oor.
Install no higher than 96" (2.4 m) from bottom of washer.
Secure the guide to the side of the basin wall with a
hook or to the tap with a piece of string to prevent the
drain hose from moving.
Stand pipe
Hose retainer
4"
(100 mm)
39" Min
(99 cm)
Tie strap
Hose
4"
retainer
(100 mm)
96" Max
39" Min
Tie strap
installing your washer _17
2012-11-13
2012-11-13
5:58:09