Campbell Hausfeld XT251000 Manual De Instrucciones página 11

Esmeriladora recta angular
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

GENERAL TROUBLESHOOTING GUIDE
SYMPTOM
Tool runs slowly or will
not operate
Moisture blowing out
of tool
Excessive vibration
POSSIBLE CAUSE(S)
1.
Grit or gum in tool
2.
No oil in tool
3.
Low air pressure
4.
Air hose leaks
5.
Pressure drops
6.
Regulator adjusted wrong
7.
Worn ball bearing in motor
or in angle head
8.
Worn gears
1.
Water in tank
2.
Water in the air lines/hoses
1.
Damaged stone or burr
2.
Collet shaft bent
CORRECTIVE ACTION
1.
Flush the tool with Campbell
Hausfeld air tool oil, gum solvent, or
an equal mixture of SAE 10 motor
oil and kerosene. Lubricate the
tool after cleaning with Campbell
Hausfeld (or comparable) air tool oil.
2.
Lubricate the tool according to
the lubrication instructions in this
manual.
3.
Adjust the compressor regulator to
90 PSI while the tool is running free.
4.
Tighten and seal hose fittings, if leaks
are found.
5.
Be sure hose is properly sized. Long
hoses or tools using large volumes of
air may require a hose with an I.D. of
1/2 inch or larger depending on total
hose length.
6.
Adjust air flow regulator with a
flathead screwdriver to maximum
speed.
7.
Replace tool.
8.
Replace tool.
1.
Drain tank (See air compressor
manual). Oil tool and run until no
water is evident. Oil tool again and
run 1-2 seconds.
2
a. Install a water separator/filter.
NOTE: Separators work properly
only when air passing through
the separator is cool. Locate
separator/filter as far as possible
from compressor.
b. Install an air dryer.
c.
Anytime water enters the
tool, the tool should be oiled
immediately.
1.
Replace with new stone or burr.
2.
Replace tool.
9 9

Publicidad

Tabla de contenido
loading

Tabla de contenido