SEVERIN KS 9876 Instrucciones De Uso página 14

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 38
1.
Temperature control
2.
On/Off switch for interior light
3.
Interior light
4.
Storage shelves (height-adjustable)
5.
Zero-degree zone
6.
Glass storage shelf
7.
Vegetable/fruit fresh storage compartment
8.
Freezer tray
9.
Quick-freeze compartment
10. Freezer compartments
11. Freezer unit melt-water drain
12. Egg storage
13. Door storage
14. Condenser
15. Melt-water evaporation tray
16. Compressor
17. Support rails for zero-degree zone compartment
The 'zero-degree zone' compartment (5) sits on two support
rails (17) and can be easily pulled out and removed.
Before using for the fi rst time
∙ Remove any exterior and interior packaging materials
completely, including the red transport securing devices.
∙ The packaging materials must be properly disposed of.
∙ NOTE: When the door to the freezer unit is opened, a small
red component will fall out; this is for transport only and can
be disposed of.
∙ Fit the two spacer
elements (provided) into
the corresponding guide
slots on the rear.
∙ Before it is connected to
the mains, the unit must
be thoroughly checked for
transport damage, including its power cord.
∙ Clean the unit as described in the section De-frosting and
cleaning.
∙ For positioning, we recommend that you tilt the unit slightly
backwards. In this way, the transport rollers can be used to
move it to its intended place of installation.
∙ The unit should only be transported in its vertical position;
do not tilt any more than 30°.
∙ Once the unit has been positioned, wait for about 30
minutes before it is connected to the mains.
∙ If the unit has been tilted more than 30° during transport,
allow it to stand upright for at least 4 hours before it is
connected to the mains.
∙ When the unit is fi rst switched on, a slight 'new' smell may
be noticed. However, this will disappear once the cooling
process has begun.
Installation
∙ The appliance should be set up in a well-ventilated, dry room.
∙ It should be operated in conditions where the relative
humidity is no more than 70 %.
∙ The product data sheet contains details of the ambient
temperature range suitable for this appliance.
∙ Do not use the appliance outdoors.
14
∙ Ensure that the plug is accessible and can be removed from
the wall socket at any time.
∙ Do not expose the appliance to direct sunlight, and do not
position it next to any heat sources (radiators, cookers etc). If
this cannot be avoided, however, suitable insulation must be in
installed between the heat source and the unit.
∙ The unit must not be installed inside a cabinet, nor directly
below a hanging cupboard, shelf or similar object.
∙ In the case of uneven fl oors, the adjustable feet on the unit
can be used to compensate and ensure optimum stability.
∙ If the unit is installed next to a wall, a minimum lateral
distance of 225 mm is necessary, so that the doors can open
wide enough for the drawers to be taken out.
Set-up dimensions
Ventilation
The heated air around the rear of the unit must be able to
circulate freely. Therefore, ensure that the air circulation behind
the unit is not obstructed.
Caution: Ensure at all times that the rear ventilation
openings around the top cover are not obstructed.
Reversible door
If required, the door may be reversed, i.e. from right-hinged (default

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Ks 9877

Tabla de contenido