Page 5
New Construction Installation
5
Connect Wires and Install Knockout Plate
• Run 120VAC electrical wiring to the installation location.
• Use proper UL-approved connectors to secure wiring to the Knockout Plate provided in Parts Bag.
• Connect wires as shown in wiring diagram.
Fan
LIGHT
SWITCH
LINE
IN
MANUAL
ON
SENSOR/
CONTROL
MASTER
BLK
LINE
WHT
IN
GRD
1
Attach cable clamps to Knockout
Plate. Knockout Plate mounts to
outside of Housing and may be
oriented as desired.
Light
2
Connect wires
LIGHT WITH ON/OFF SWITCH
14/2
FAN
MANUAL
ON
FAN
MASTER &
SENSOR/
CONTROL
BLK
WHT
GRD
14/3
SWITCH BOX
LIGHT WITH DIMMER SWITCH
DIMMER
SWITCH
SWITCH BOX
BLK
BLU
LIGHT
WHT
ORG
SENSOR
RED
CONTROL
BRN
BLK
BLK
FAN
WHT
BLK
GRD
UNIT
14/2
BLK
BLU
WHT
RED
ORG
BRN
BLU
BLK
BLK
WHT
GRD
14/4
ZB80ML1 n ZB110ML1 Installation Guide
3
4
Screw from
Parts Bag
WHT
WHT
WHT
LIGHT
SENSOR
CONTROL
BLK
FAN
WHT
UNIT
• See OPERATION
section on page 12 for
details.
• MASTER switch
turns fan system
on and shuts it off
for fan cleaning
and maintenance
purposes.
• SENSOR/CONTROL
switch turns motion
control automatic
operation on/off.
• MANUAL-ON switch
directly increases fan
operation to certified
airflow rate.
• MASTER and
SENSOR/CONTROL
switches can be
combined (see page
10).
• Motion sensor can be
wired to control light
(see page 10).
• MASTER switch along
with or separate from
SENSOR/CONTROL
switch may be located
where they are not
easily accessed for
everyday usage;
they may need to be
labeled and located
where they can't be
turned on without
being seen from fan to
comply with local and
national codes.