9. Specifications
Specifications
Accuracy, switching output
EN
Temperature error in nominal
temperature range
Temperature coefficients in nominal temperature range
Mean TC zero point
Mean TC span
Reference conditions (per IEC 61298-1)
Ambient temperature
Atmospheric pressure
Air humidity
Power supply
Mounting position
Operating conditions
Permissible temperature ranges
Medium
Ambient
Storage
Nominal temperature
Air humidity
Vibration resistance
Shock resistance
30
≤ ±1.0 % of span
maximum: ≤ ±1.5 % of span
maximum: ≤ ±2.5 % of span for increased overload safety
≤ ±0.16 % of span/10 K
≤ ±0.16 % of span/10 K
15 ... 25 °C [59 ... 77 °F]
860 ... 1,060 mbar [12.5 ... 15.4 psi]
45 ... 75 % r. h.
DC 24 V
Process connection lower mount
-25 ... +85 °C [-13 ... +185 °F]
Option: -40 ... +125 °C [-40 ... +257 °F]
1) Medium temperature restricted to -30 ... +85 °C [-22 ... +185 °F] with UL approval
-20 ... +85 °C [-4 ... +185 °F]
With ambient temperatures less than -20 °C [-4 °F], the turning of the display head and button
operation is not permitted.
-40 ... +70 °C [-40 ... +158 °F]
-20 ... +80 °C [-4 ... +176 °F]
45 ... 75 % r. h.
20 g, 10 ... 2,000 Hz (IEC 60068-2-6, under resonance)
50 g, 6 ms (IEC 60068-2-27, mechanical)
1)
WIKA operating instructions, model PSD-4-ECO