18. Remove the connector installed in step 10 and insert a plug into Port #1.
Remove the manifold adapter pin and insert a plug into Port #2.
19. Remove the connector installed in step 10 from the tubing attached to the
storage tank. Connect the storage tank tubing to the port marked "Tank"
on the biofilter manifold.
20. Remove the sanitization cartridge from the prefilter (leftmost) position and
install the remaining sanitization cartridge that was prepared in Step 1 in
the prefilter position. Slowly open the water supply valve, tank valve and
drinking tap in that order.
21. Run the system for five (5) minutes, then shut off the water supply valve.
Drain the storage tank to depressurize the system, then close the drinking tap.
Bring System On Line
22. Remove the sanitization cartridges from the prefilter and postfilter posi-
tions. Remove all packaging from the new prefilter cartridge and install it
into the prefilter position. Install the postfilter cartridge, that was set aside
in step 8, in the postfilter position.
23. Slowly turn on the water supply valve and fill the storage tank. This will
take several hours.
24. Open the drinking water system tap to empty the tank, and discard the first
tank of product water.
25. Your system is now ready to produce clean, biopure water!