SL
WARNINGS FOR THE USER
In the event of a fault or malfunctioning, disconnect the power supply upstream of the control unit and call technical
service.
Periodically check functioning of the safety devices. Any repairs must be carried out by specialised persons using
original and certified materials.
The product may not be used by children or persons with reduced physical, sensorial or mental abilities, or persons
without experience and knowledge of the product unless correctly instructed.
Do not access the board for adjustments and/or maintenance.
WARNING: IMPORTANT SAFETY INSTRUCTIONS.
It is important for the safety of persons to follow these instructions.
Keep this instruction manual.
ELECTRICAL EQUIPMENT
1- Gearmotor; 220-230V power supply, 3x1.5mm² cable (comply with the current standards)
2- Photocell transmitter 2x0.5mm² cable
3- Photocell receiver 4x0.5 mm² cable
4- Antenna screened coaxial cable.
5- Frame 4x0.5mm² cable
6- Rack
7- Key selector 3x0.5mm² cable
8- 24 VDC flashing light signaller 2x0.75mm² cable (if 12x0.75 mm² RX cable is present)
9- Omnipolar magnetothermal switch with minimum contact opening of 3 mm Power supply line to the control unit
220-230V, 50-60Hz, 3x1.5 mm² cable (comply with the current standards).
TECHNICAL DATA
Operator
Type
Supply voltage
Motor power supply
Power absorbed
Current absorbed
Thermal cutout
Pick-up capacitor
Max speed
Maximum torque
Operating temperature
Degree of protection
Operating frequency (%)
Maximum leaf length
Encoder
SL 544
Irreversible electromechanical gearmotor
220/230Vac 50-60Hz
24Vdc
MAX 100W
MAX 4A
-
-
0,2 m/sec
12 N/m
-20°C + 60°C
IP 55
90% (a 20°C)
6 m
Integrated into the motor
15