PERFORMANCE DATA

Important Notice: Read performance data and compare the
capabilities of the system with your actual water treatment
requirements. It is recommended that the supply water be tested,
before installing a water treatment system, to determine your water
treatment needs.
Test Conditions
Flow Rate
F1000-DFB
= 0.75 gpm (2.83 L/min)
F1000-B1B
= 0.60 gpm (2.27 L/min)
Filter Capacity
F1000-DFB
= 750 gallons (2839 L)
F1000-B1B
= 750 gallons (2839 L)
Inlet Pressure
= 60 psi (4.1 bar)
Temperature
= 68°F +/- 5°F (20°C+/- 2.5°F)
Testing was performed under standard laboratory conditions, actual
performance may vary.
Operating Requirements for F1000-DFB and F1000-B1B Systems:
Pressure
= 40-100 psi (2.75–6.89 bar)
Temperature
= 40-100°F (4.4–37.8°C)
F1000-DFB SYSTEM INSTALLED WITH
FDF1-RC FILTER CARTRIDGE
This system have been tested according to NSF/ANSI 42 for
reduction of the substances listed below. The concentration of the
indicated substances in water entering the system was reduced to
a concentration less than or equal to the permissible limit for water
exiting the system, as specified in NSF/ANSI 42.
Model F1000-DFB
Max. Permissible
Influent Challenge
Substance
Product Water
Concentration
Concentration
Standard 42
Chlorine
2.0 mg/L±10%
Taste & Odor
Flow Rate = 0.75 gpm (2.8 L/min); Capacity = 750 gallons (2839 L) or 12
months
Testing was performed under standard laboratory conditions, actual
performance may vary.
The Model F1000-DFB is Tested and Certified by NSF International
against NSF/ANSI Standard 42 and CSA B483.1 for the reduction
of substances specified on the Performance Data Sheet.
C
US
Reduction
Minimum
Average
Requirements
Reduction
Reduction
≥50%
88.8%
FRESHPOINT F1000-DFB, F1000-B1B Filtration Systems Instruction Manual • 9
CARTRIDGE SEQUENCE
F1000-DFB
F1000-B1B SYSTEM INSTALLED WITH
F1B1- RC FILTER CARTRIDGE
This system has been tested according to NSF/ANSI 42 and 53 for
reduction of the substances listed below. The concentration of the
indicated substances in water entering the system was reduced to
a concentration less than or equal to the permissible limit for water
exiting the system, as specified in NSF/ANSI 42 and 53.
Model F1000-B1B
Max. Permissible
Influent Challenge
Substance
Product Water
Concentration
Concentration
Standard 42
Chlorine
2.0 mg/L±10%
Taste & Odor
Particulates
at least 10,000
(0.5-<1uM)
particulates/mL
Class 1*
Standard 53
Cysts **
Minimum 50,000/L
Atrazine
0.009 mg/L ± 10%
0.003 mg/L
Lead (pH
0.15 mg/L ± 10%
0.010 mg/L
6.5)
Lead (pH
0.15 mg/L ± 10%
0.010 mg/L
8.5)
Lindane
0.002 mg/L ± 10%
0.0002 mg/L
Flow Rate = 0.6 gpm (2.2 L/min); Capacity = 750 gallons (2839 L) or 12
months
Testing was performed under standard laboratory conditions, actual
performance may vary.
* Reduces particles as small as 0.5-1 micron in size by mechanical
means
** NSF/ANSI Standard 53 certified to redcue cysts such as
Cryptosporidium and Giardia by mechanical means.
The Model F1000-B1B is Tested and Certified by NSF International
against NSF/ANSI Standard 42, 53, and CSA B483.1 for the
reduction of substances specified on the Performance Data Sheet.
C
US
EPA Est. 082989-CHN-001
F1000-B1B
Reduction
Minimum
Average
Requirements
Reduction
Reduction
95.9%
≥50%
>85%
97.9%
99.95%
99.97%
99.99%
90.5%
93.7%
99.3%
99.9%
99.3%
99.6%
94.8%
97.4%