COLORdash™ Par-Quad 7 QRG
Power Linking
AC Plug
Fuse
Replacement
DMX Linking
DMX Connection
Master/Slave
Connection
Mounting
Product
Mounting
Diagram
Control Panel
Description
You can link up to 21 COLORdash™ Par-Quad 7 products at 120 VAC or
39 at 230 VAC. Never exceed this number. Power linking cords can be
purchased separately.
Connection
AC Live
AC Neutral
AC Ground
1. Disconnect this product from power.
2. Using a flat-head screwdriver, unscrew the fuse holder cap from the
housing.
3. Remove blown fuse and replace with a good fuse of the same type and
rating.
4. Screw the fuse holder cap back in place and reconnect power.
The COLORdash™ Par-Quad 7 will work with a DMX controller using a
regular DMX serial connection. A DMX Primer is available from
www.chauvetprofessional.com.
The COLORdash™ Par-Quad 7 uses a regular DMX data connection for its
DMX personalities: 4 Ch, 6 Ch, and 10 Ch. See the User Manual to
connect and configure for DMX operation.
The COLORdash™ Par-Quad 7 uses the DMX data connection for its
Master/Slave mode. See the User Manual to connect and configure for
Master/Slave operation.
Before mounting this product, read the
mounting clamp is capable of supporting the weight of the product. For our
Chauvet line of mounting clamps, go to
plates-accessories-clamps/.
Overhead Mounting
Button
<MENU>
Exits from the current menu or function
Enables the currently displayed menu or sets the currently
<ENTER>
selected value into the selected function
Navigates upwards through the menu list or increases the
<UP>
numeric value when in a function
Navigates downwards through the menu list or decreases
<DOWN>
the numeric value when in a function
Wire (U.S.)
Wire (Europe)
Black
White
Green/Yellow
Green/Yellow
3
Screw Color
Brown
Yellow/Brass
Blue
Safety
Notes. Make sure the
trusst.com/productcategory/base-
Secure the safety cable using
the passageway on the back
of the product.
Floor Mounting
Function
EN
Silver
Green