IMPIANTO ELETTRICO - ELECTRICAL SYSTEM - SYSTÈME ÉLECTRIQUE - ELEKTRISCHE ANLAGE -
INSTALACIÓN ELÉCTRICA - ЭЛЕКТРИЧЕСКАЯ СИСТЕМА - ΗΛΕΚΤΡΙΚΗ ΜΟΝΑΔΑ -
Impianto elettrico
Caratteristiche elettriche e limite di utilizzo dell'alimentatore:
- Input: 100-240 V ac, 50-60 Hz, 1,1 A
- Output: 5V dc, 3A (max)
- Temperatura di esercizio: -20°C ÷ 50°C
Caratteristiche elettriche LED RGBW e limite di utilizzo del faretto:
- RED - 50 lm typical @ 300 mA/Ta =25°C, ±10%
- GREEN - 20 lm typical @ 300 mA/Ta =25°C, ±10%
- BLUE - 60 lm typical @ 300 mA/Ta =25°C, ±10%
- WHITE - 80 lm typical @ 300 mA/Ta =25°C, ±10%
- Temperatura di esercizio del Led RGBW: -30°C ÷ +85°C
- Temperatura di esercizio del faretto: 0°C ÷ +45°C
- Potenza assorbita: da 4W a 7W a seconda del colore selezionato (con luminosità al 100%)
A - CENTRALINA E TRASFORMATORE - fornita in dotazione (Installabile solo nella "zona di sicurezza" Z3)
B - TASTIERA DI COMANDO LUCE - fornita in dotazione (Installabile nelle zone Z1 / Z2 / Z3) - due pulsanti da 1 polo
con contatto normalmente aperto (Installabile solo nella "zona di sicurezza" Z3)
C - SCATOLETTA PASSACAVO (Installazione vincolata alla zona Z1 / Z2)
Cavo da "A" a "B":
Lunghezza massima = 7 m
Sezione = 0.2 mmq
Poli = 6
ATTENZIONE:
- é obbligatorio il collegamento ad un salvavita con corrente di intervento non superiore a 30mA.
- sul cavo di alimentazione "L+N" (non in dotazione), per garantire il rispetto dei requisiti di Compatibilità
Elettromagnetica, è necessario posizionare la seguente ferrite:
Marca: Fair-Rite Products Corp - Modello: 431164281 o un componente con caratteristiche analoghe.
Electrical system
Electrical characteristics and limit of use of the power source:
- Input: 100-240 V ac, 50-60 Hz, 1,1 A
- Output: 5V dc, 3A (max)
- Operating temperature: -20°C ÷ 50°C
Electrical characteristics LED RGBW and limit of use of the spot:
- RED - 50 lm typical @ 300 mA/Ta =25°C, ±10%
- GREEN - 20 lm typical @ 300 mA/Ta =25°C, ±10%
- BLUE - 60 lm typical @ 300 mA/Ta =25°C, ±10%
- WHITE - 80 lm typical @ 300 mA/Ta =25°C, ±10%
- Operating pressure of the Led RGBW: -30°C ÷ +85°C
- Operating pressure of the spot: 0°C ÷ +45°C
- Absorbed power: from 4W to 7W according to selected color (with 100% luminosity)
A - POWER UNIT AND TRANSFORMER - supplied (For installation only in the "safety area" Z3)
B - LIGHT CONTROL KEYBOARD - supplied (For installation in the areas Z1 / Z2 / Z3) - two 1-pole buttons with
normally open contact (For installation only in the "safety area" Z3)
C - CABLE GLAND BOX (Installation for area Z1 / Z2)
Cable from "A" to "B":
Maximum length = 7 m
Section = 0.2 mmq
Poles = 6
WARNING:
- the connection to the cutout box is mandatory with intervention current not higher than 30mA.
- on the supply cable "L+N" (not supplied), to guarantee compliance with Electromagnetic Compliance
requirements, position the following ferrite:
Brand: Fair-Rite Products Corp - Model: 431164281 or a component with similar characteristics.
Cavo da "A" a "C":
Lunghezza massima = 8 m
Sezione = 0.5 mmq
Poli = 5
Cable from "A" to "C":
Maximum length = 8 m
Section = 0.5 mmq
Poles = 5
16
电气设备