Technical data
– Supply voltage:
– Required electrical outlet:
– Max. power consumption:
Prod. No.:
- 13601 17115X:
- 13601 17125X:
Maximal load mirror cabinet total:
- 13601 17115X:
- 13601 17125X:
– Degree of protection:
– Ambient conditions:
Operating temperature
Storage temperature
– Luminous color
Mounting dimensions, see page 8.
CAUTION: Risk of personal injury: This
product is very heavy. Get assistance lifting the
cabinet.
Included items, refer to picture 1 on page 9.
WARNING - GROUNDING
INSTRUCTIONS
This product must be connected to a grounded me-
tal, permanent wiring system, or an equiment-groun-
ding conductor must be run with the circuit con-
ductors and connected to the equipment-grounding
terminal or lead on the product.
Wiring diagram, refer to picture 2 on page 9
The product can be operated in two ways.
Operating mode 1 (condition as supplied):
Light on/off on rotary dimmer of the product
(automatically off after power reinstated).
Operating mode 2:
Light on/off on external light switch (automatically on
after power reinstated).
To toggle the operating mode, press and hold the
rotary dimmer 15 seconds while the light is switched
off. The light turns on briefl y to confi rm the change to
the operating mode.
Lighting modes
The product has 3 different lighting modes.
Mode 1: Front illumination
Mode 2: Washbasin illumination
Mode 3: Front and washbasin illumination
Press the rotary dimmer for at least one second to
change the lighting modes.
120 V AC / 50/60 Hz
15 A / 1800 VA
Width
Weight
Light
16-15/16"
35.3 lb
16-15/16"
35.3 lb
48.50 lb
48.50 lb
NEMA 1
32° – 113° F
-40° – 158° F
3000 Kelvin
Installation
Before installation check whether the fastening mate-
rials included are suitable for the anchoring base. The
fastening materials are suitable exclusively for stud walls
with timber constructions or for drywall constructions with
timber wood reinforcement.
21 W
• Do not remove protective edge before mounting
21 W
the top light, see picture 3 on page 10.
• Connect top light to mirror cabinet, see picture 4.
• Mount top light to mirror cabinet, see picture 5.
• Mark the wall bracket position, see picture 6.
• Mount the wall brackets to the wall, see picture 7.
• Hang the mirror cabinet on the wall from above,
see picture 8 on page 11.
• Draw holes for fi xing screws, see picture 9.
• Remove mirror cabinet, see picture 10.
• Drill holes and insert wall plugs, see picture 11.
• Connect the mirror cabinet to the power supply,
see picture 12.
• Hang the mirror cabinet on the wall from above,
see picture 13.
• Insert sleeves, screw in screws and cover with
caps, see picture 14 on page 12.
• Place the glass shelf holders in the mirror cabinet,
see fi gure 15.
• Place the glass shelves in the mirror cabinet,
see fi gure 16.
• Adjust the doors of the mirror cabinet, see fi gure 17,
18 and 19 on page 12 and 13.
Operation, refer to picture 20 on page 13
Note: When switching off the lights, the type of
lightning and its intensity are saved and will be
the same after switching on the lights again.
Replacement parts with order numbers, see page 15.
The light sources may only be replaced by the
manufacturer, its customer service or by an
equally qualifi ed person.
For information about warranty and mainte-
nance, see the enclosed Care Instructions and
Warranty Card.
Disposal instructions
This category of device does not belong in
the domestic waste, but must be disposed of
separately in accordance with the relevant local
national regulations.