Sistemi Elettronici
di Apertura Porte e Cancelli
International registered trademark n. 804888
2) Foundation plate anchoring
- Make a 500 x 500 x 300 mm (depth) hole in the ground.
- Fill the hole with R425 concrete and place the foundation plate as shown
in Fig. 3.
- Accurately level the plate.
* The middle hole of the plate must be used for cable routing. Therefore,
make sure that the conduit connected to the hole complies with current
regulations, before filling the hole with concrete.
Conduit
Concrete
3) Post anchoring on the foundation plate
-
Place the casing so that the holes on the base match the screws located on the
foundation plate.
Make sure that the conduit for the cables goes through the large hole of the casing
-
base.
Insert the bracket for anchoring the spring: A in case of left-hand mounting, B in
-
case of right-hand mounting; the bracket must always be positioned towards the
inside as in Fig.6.
Fix the casing on the foundation plate, screwing the supplied nuts and washers
-
carefully.
A
Hole for the conduit containing
®
500
Anchoring nuts
B
the electrical cables
Foundation plate
to be levelled
Fig.3
and washers
English
Fig.4
3 0 m m
Fig.5
Fig.6
13