• Always disconnect the LED fixture from mains before performing any maintenance.
• Always allow for a cool down period of at least 20-30 minutes before touching the LED light bars. Touching
the LED bars when the fixture is lit or immediately after may result in burns!
• Natural convection removes heat away from the heatsink. In order for the system too properly cool itself,
at least 5cm of space is required between the fixture and the roof of your grow area. Do not use abrasive
materials or aggressive cleaning agents to clean the LED fixture as this may damage
the secondary optics. Instead use a clean dry fabric/cloth.
• Do not use the LED fixture near flammable, explosive or reactive substances. The LED fixture can reach
temperatures of 40ºC.
• Do not use sulphur vaporizers or water misters.
• The installation and use of the LED fixture is the responsibility of the end user. Incorrect use or installation can
lead to failure and damage to the LED fixture. Damage to the LED fixture and electronic circuitry as a result
of incorrect installation and use revokes the warranty.
5. CONTENTS
1x MANUAL
2x METAL CABLE HANGERS
1x DIMMING
CONTROLLER 0 -10V
Connects to SIGNAL IN
connector on Frame B
1x LED FRAME B
Contains power inputs &
dimming self-locking male
connectors and control signal ports
6. INSTALLATION
Warning! Mounting and installing the LED fixture must be in accordance with the applicable local laws and
regulations.
Warning! The installer is responsible for correct and safe installation.
Warning! Ensure the local cabling can support the voltage and current requirements of the LED fixture.
Warning! Avoid coiled cables and keep mains leads separated to help prevent electromagnetic interference.
Warning! Do not connect or disconnect the LED fixture under load.
1x LED DRIVER
Position power output &
dimming female connectors toward
frame B and power supply input male
connector toward Frame A
1x LED FRAME A
1x SUPPORT FRAME
(contains LED driver mounting bracket)