Set-Up And Operation - U.S. Products SOLUS 310R-PFR Instrucciones De Uso

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

A - ENGLISH

SET-UP AND OPERATION

CAUTION!
Use care when handling hazardous chemicals.
Never leave the machine running when you are not actively using it.
To avoid vacuum motor damage, always make sure the fl oat fi lter is clean and that it can travel freely before you operate the machine. Always
use a defoamer any time foam is present.
DANGER!
Do NOT use solvents, or any chemicals that may be fl ammable, explosive or combustible.
CLEANING SOLUTIONS:
Select a proper pre-spray for the surface to be cleaned, and apply the pre-spray. Use a neutral pH rinse or detergent (6 to 10 pH) in the unit to
prevent premature wear of the pumps, seals, and other components. Damage caused by the use of improper or strong chemicals is not covered
by warranty. Powdered chemicals are not recommended.
1.
Fill the holding tank (2) with clear water and pre-spray with the detergent of your choice (we recommend a CRI approved chemical). Mix well.
Although this machine is designed to supply instant hot water, the addition of warm water to the holding tank would increase heater effi ciency.
Never use water above 130º F/54º C in the solution tank.
2.
Turn off all the switches. Plug in cord #1. (This cord runs the pump and vacuum). NOTE: TURN THE HEAT RECIRCULATION SWITCH
OFF BEFORE PRIMING THE PUMP.
3.
Attach the priming hose to the Solution Hose Quick Connect (10) and place the open end into the vacuum tank.
4.
Turn on the pump (G) and let it run until the pump is fully primed (approximately 30 seconds to 1 minute). Once the pump is primed, turn off
the pump and disconnect the priming hose. Attach the cleaning hose (3 & 10) and tool.
IF YOU WANT HEATED SOLUTION:
5.
Plug in the heater cord (identifi ed by "H" on the back of the machine). NOTE: If the Separate Circuit Locator Light (C) does not illuminate
when the heater cord is plugged in, then both cords are on the same circuit. Try other outlets until the light comes on. See Bypass Switch
section (below) if you are unable to get a green light.
IF YOU WANT TO PRE-HEAT THE SOLUTION IN THE HOLDING TANK:
6.
Turn on both the pump (G) and heat recirculation switches (A). NOTE: this switch will recirculate heated water back to the holding tank, until
it reaches 125 °F. At that point, the recirculation will automatically stop. If the temperature of the water in the tank drops below 125 °F, and if
the recirculation switch is still turned ON, the system will begin to recirculate the water again until it gets back up to 125 °F. You can choose
to let the solution in your holding tank reach 125° or you can choose to begin cleaning sooner than that.
NOTE: the time that it will take for your solution to reach 125 °F will vary with the temperature of the solution that you put into the tank, the
ambient temperature, the amount of solution in your tank, etc.
YOU MUST TURN THE HEAT RECIRCULATION SWITCH OFF BEFORE YOU CAN PRIME THE PUMP AND BEFORE YOU BEGIN
CLEANING, OTHERWISE YOUR PUMP PRESSURE WILL BE VERY LOW.
7.
Turn on the pump (G) and spray through your tool a few times to fi ll the lines with solution. Begin cleaning.
8.
Refi ll and empty the tanks as necessary.
9.
When fi nished with the job, vacuum all unused solution into the recovery tank, and dump the tank. Clean the tanks and fi lters. Clean the tool
and hoses. Store the machine in a heated location.
SEPARATE CIRCUIT LOCATOR
This unique, patented "smart system," operated by a solid state circuit, will inform the operator when the two cords are plugged into separate lines
by illuminating the green, indicator light. This helps prevent tripping circuit breakers.
BYPASS SWITCH
The Bypass Switch (D) completely bypasses the separate circuit locator system. Use this feature when you cannot get the green Circuit Locator
(C) to come on and you believe that the two cords are on separate circuits.
CAUTION:
If the bypass switch is on when the two cords are plugged into the same circuit, the breaker in the wall panel may trip.
8
INSTRUCTIONS FOR USE
SOLUS
310R-PFR - 56091035
®
5/08