PRE-OPERATION CHECKLIST
Pre-Operation
ENGINE OIL
Before checking or refilling oil, be sure generator is located on stable
and level surface with engine stopped. This generator uses SAE
10W30 oil.
1. Remove oil dipstick and check the engine oil level.
2. If oil level is below the lower level line, refill with suitable oil to upper
level line. Do not screw in the oil dipstick when checking oil level.
3. Change oil if contaminated.
Always check the level of the engine oil prior to start-
ing the generator.
•
Failure to do so could cause the engine to seize if the oil is low or
empty.
High Mark
Operating Range
FUELING
Explosive Fuel! Gasoline is extremely flammable and
its vapors can explode if ignited.
•
DO NOT refuel while smoking or near open flame or other such
potential fire hazards.
•
Store gasoline only in approved containers, in well ventilated,
unoccupied buildings and away from sparks or flames.
•
DO NOT fill the tank while the engine is hot or running, since
spilled fuel could ignite if it comes in contact with hot parts or
sparks from ignition.
•
DO NOT start the engine near spilled fuel.
•
NEVER use gasoline as a cleaning agent.
NOTICE
Low Mark
WARNING
15