rent humidity.
► Press humidity up or down key to adjust the
humidity needed. If the set humidity is 3% less
than current humidity, the unit runs; if the set hu-
midity is 3% more than current humidity, the unit
stops running.
► When set humidity is less than 30%, the unit
dehumidifies continuously, and the humidity dis-
play window reads "CO".
SHUT OFF:
► Press "ON/OFF" when the unit is running, the
unit stops running and all indicators die.
NOTICES:
► When the set humidity is higher than current
humidity, the unit will not run.
► When the tank is full, the tank full indicator
lights on, meanwhile, the compressor and the
fan motor shut off automatically, and the buzzer
gives off "DD" sound. Unless the tank is emp-
tied, the buzzer gives the "DD" sound every 5
minutes. Only after emptying the tank the unit
will start running again.
► When dehumidifying, the fan motor and com-
pressor must be running at least for 3 minutes,
once the compressor starts on. It is strongly for-
bidden to restart the compressor again within 3
minutes after the shut off.
► When operating in low temperature, the unit
judges the system temperature automatically to
defrost. When defrosting, the defrosting indica-
tor lights on, the compressor runs but fan motor
shuts off automatically.
► When you press the memory key, the control-
ler will record current humidity even if the power
is off. The unit will run under previous mode af-
ter power supplied again.
► The humidity display window shows humidity
from 30% to 90%.
► Keep the unit unplugged if not used for a long
time.
CONTINUOUS DRAINAGE:
► Take out the tank, open drainage gate at the
bottom of tank, connect pipeline, fix the tank
back, and pull the pipeline out from the bottom
of the machine.
►►
4.
MAINTENANCE AND SAFETY
►
► FIG. 3
Do not use any relay, prolonged wire or adaptor.
Otherwise, it might result in fire, radiation, or an
electric shock.
► FIG. 4
Do not put the unit nearby stove or heater. Oth-
erwise parts of unit might melt down or even
catch fire.
► FIG. 5
Do not use the unit in the direct sunshine, wind
or rain. (only for indoor usage)
► FIG. 6
In case of any other problems (for example smell
of scorch ), please shut off the unit and unplug
it. Otherwise, it might result in fire, electric shock
or other malfunctions.
► FIG. 7
Do not use the unit in places easily affected by
chemicals. Strong chemicals might damage the
unit and cause the leakage.
► FIG. 8
Please unplug the unit when not used for a long
time.
► FIG. 9
When cleaning, shut off and unplug the unit.
Otherwise, it might result in an electric shock.
► FIG. 10
When draining continuously, put the drainer for
smooth drainage. If the ambient temperature is
as low as freezing, do not drain continuously.
► FIG. 11
Do not repair or disconnect the unit yourself.
Otherwise it might result in fire or an electric
shock.
► FIG. 12
Put the unit stably. If the unit turns over, the wa-
ter will flow out from the tank and damage the
objects nearby. Moreover, because of the dam-
age, it might result in fire or an electric shock
► FIG. 13
Make the filter more endurable. When off for a
long time, seal the filter in a plastic bag.
en
it
de
es
fr
nl
da
fi
no
sv
pl
ru
cs
hu
sl
hr
lt
lv
et
ro
sk
bg
uk
zh
SI
SK
TR
UA