ALIGNMENT AND ADJUSTMENTS
To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before
servicing, unless testing requires power.
Continuous Run Mode
Power On state
(Normal user mode)
How to enter:
-
Press Mixed Load Bell+ Dry Level for 7 sec during Power On State (normal user mode).
-
Once in Continuous Run Mode, display "CC" for 1 sec and the remaining time for 2 sec in
turns.
-
The previous cycle will restart during Continuous Run Mode until the mode is deactivated.
-
During Continuous Run Mode, press Mixed Load Bell+ Dry Level for 7 seconds to go back to
normal user mode.
Data Display Mode
How to Enter:
-
With Power On, press AdjustUp Key + AdjsutDown Key for 7 seconds until it sends out a
beeping sound .
-
If not pressed any keys for 5 minutes, it will be set back from Data Display Mode
-
If pressing AdjustUp Key in this mode ,Display Mode will be incresed.
-
If pressing AdjustDown Key in this mode ,Display Mode will be decresed.
Definition of Data Display Mode:
-
Display Mode 1 : Temperature data
-
Display Mode 2 : Average Touch Sensor data for 1 minute
-
Display Mode 3 : Average Temperature data for 1 minute
Technical_information-02835F_EN.indd 4
WARNING
Mixed Load Bell+ Dry Level
7 SEC
4
Continuous Run Mode
2012-05-18
4:34:40