6 - Conversion for LP or NG Gas

EN

Converting Appliance for Use with LP Gas

WARNING
Conversion is to be performed by an AUTHORIZED
SERVICER (or other qualified agency) in accordance with the
manufacturer's instructions and all codes and requirements of
the authority having jurisdiction. Failure to follow instructions
could result in serious injury or property damage.
The qualified agency performing this work assumes
responsibility for this conversion.
CAUTION
Before proceeding with the conversion, shut off the gas supply
to the appliance prior to disconnecting the electrical power.
If this appliance is to converted for use with gas LP (propane
or butane), each of the following modifications must be
performed:
Gas conversion label (aluminium) to be placed on the back of
the appliance, near the data plate, after conversion has been
carried out;

Replace Injectors (two ring flame burner)

1. Remove the grates and burner caps.
2. Remove aluminium gas spreader.
3. Remove the three screws from the simmer gas spreader
(1).
4. Remove the two screws of the injector cover (2).
5. Remove injector (A) by using a 9-32" (7mm) nut driver
counter clockwise.
6. Remove injector (B) by using a 9-32" (7mm) box wrench
counter clockwise.
7. Install the injectors supplied with this appliance in the
appropriate burner. The injectors have small numbers
stamped on the side, this number corresponds with the
orifice diameter and its correct burner location (refer to
illustrations in the section: "Injectors Position").
8. Turn clockwise to tighten (tighten to a torque of 15 to 20
inch-lbs).
9. Replace all parts following the reverse order.
10. Save the injectors removed from the appliances for
future use.
14
EXPLODED VIEW DUAL BURNER
1
2
A

Replace injector on (one ring flame burners)

1. Remove the grates and burner cups.
2. Remove aluminum gas spreader.
3. Loosen injector by turning 9-32" (7 mm) nut driver counter
clockwise.
4. Install the injectors supplied with this appliances in the
appropriate burner. The injectors have small number
stamped on the side, this number codes the orifice diameter
and its correct burner location (see figure on page 16).
5. Turn clockwise to tighten (tighten to a torque of 15 to 20
inch-lbs).
6. Replace all parts following the reverse order.
7. Save the orifices removed from the appliance for future
use.
EXPLODED VIEW SINGLE BURNER
B

Publicidad

Tabla de contenido
loading