SPECIFICATIONS
Model
Type
Power Supply
Electric Consumption
Ice Production per 24h
Dimensions
Refrigerant
Insulation Foam Blowing Agent
Weight
Ambient Temp
Water Supply Temp
Water Supply Pressure
Voltage Range
Model
Type
Power Supply
Electric Consumption
Ice Production per 24h
Dimensions
Refrigerant
Insulation Foam Blowing Agent
Weight
Ambient Temp
Water Supply Temp
Water Supply Pressure
Voltage Range
Note: The above specifications are for the representative models.
This product includes a hermetically sealed refrigeration system that contains fluorinated greenhouse gases.
IM-240ANE
Air-cooled, cube ice
1 phase 220 - 240V 50Hz
1320W
220kg (5mm) / 240kg (15mm)
(ambient temp 10°C, water temp 10°C)
560mm(W) x 700mm(D) x 880mm(H)
R404A, 0.48kg
(GWP: 3920, CO2: 1.882t)
HFC-free
Net: 80kg (Gross: 95kg)
1 - 40°C
5 - 35°C
0.07 - 0.78 MPa (0.7 - 8 bar)
Rated voltage ± 6%
IM-240ANE
Air-cooled, cube ice
1 phase 220 - 230V 60Hz
1320W
220kg (5mm) / 245kg (15mm)
(ambient temp 10°C, water temp 10°C)
560mm(W) x 700mm(D) x 880mm(H)
R404A, 0.55kg
(GWP: 3920, CO2: 2.156t)
HFC-free
Net: 80kg (Gross: 95kg)
1 - 40°C
5 - 35°C
0.07 - 0.78 MPa (0.7 - 8 bar)
Rated voltage ± 10%
IM-240AWNE
Water-cooled, cube ice
1 phase 220 - 240V 50Hz
1300W
230kg (5mm) / 240kg (15mm)
(ambient temp 10°C, water temp 10°C)
560mm(W) x 700mm(D) x 880mm(H)
R404A, 0.45kg
(GWP: 3920, CO2: 1.764t)
HFC-free
Net: 83kg (Gross: 95kg)
1 - 40°C
5 - 35°C
0.07 - 0.78 MPa (0.7 - 8 bar)
Rated voltage ± 6%
IM-240AWNE
Water-cooled, cube ice
1 phase 220 - 230V 60Hz
1130W
215kg (5mm) / 240kg (15mm)
(ambient temp 10°C, water temp 10°C)
560mm(W) x 700mm(D) x 880mm(H)
R404A, 0.40kg
(GWP: 3920, CO2: 1.568t)
HFC-free
Net: 83kg (Gross: 95kg)
1 - 40°C
5 - 35°C
0.07 - 0.78 MPa (0.7 - 8 bar)
Rated voltage ± 10%
9
ENGLISH