Cembre HT81-U Manual De Uso Y Mantenimiento página 6

Herramienta hidraulica de compresion
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

ENGLISH
4. MAINTENANCE
Air in the hydraulic circuit may affect the performance of the tool; e.g. no lower die advancement,
slow advancement of the lower die or lower die pulsation.
In this case proceed as follows:
4.1) To purge air bubbles from hydraulic circuit
a – Hold tool upright in a vice with handles open (Fig.4).
b – Using an hexagonal 2,5 mm key, remove screw (59) and main handle (04) to expose oil reservoir
(03).
c – Remove reservoir cap (01).
d – Operate the moveable handle (51) three or four times to advance the ram (34).
e – Depress pressure release pin (67) until ram is fully retracted.
f – Repeat points (d - e) at least five times, to ensure all air bubbles in the hydraulic circuit are
purged into the reservoir.
g – If the oil level is low, top up as directed in § 4.2.
h – Remove all air from reservoir and replace cap (01).
i – Assemble main handle (04) and holding screw (59).
If the tool continues to malfunction return the tool for service/repair as detailed in § 6.
4.2) Oil top up
Every six months check the oil level in the reservoir. If necessary top up, the oil level to the top lip
of the reservoir and remove all air from the reservoir, as per 4.1, points a, b, c, e, g, h and i.
Always use clean recommended oil, see § 1.
Do not use old or recycled oil.
Do not use hydraulic brake fluid.
Ensure that disposal of used oil is in accordance with current legislation.
(Ref. to Fig. 4 and 5)
6

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Ht81-ud

Tabla de contenido