EDM 73116 Instrucciones Importantes De Seguridad página 9

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

73116
REF.
INSTRUÇÕES IMPORTANTES DE SEGURANÇA / IMPORTANT SAFETY INSTRUCTIONS
CONNECTION
WARNING. DANGER OF DEATH THROUGH ELECTRIC SHOCK!
Must be installed by professional electrician.
- Disconnect power source.
- Cover or shied any adjacent live components.
- Ensure device cannot be switched on.
- Check power supply is disconnected
- Loosen the screw in the back and unload the bottom (refer to figure 1).
- Find the wire hole in the bottom and pass the power wire through hole. Connect the power wire into
connection-wire column according to the connection-wire diagram.
- Fix the bottom with inflated screw on the selected position. (refer to figure 2)
- Install back the sensor on the bottom, tighten the screw and then test it.
FIG. 1
CONNECTION-WIRE DIAGRAM (See the right figure)
TEST
- Turn the TIME knob anti-clockwise on the minimum (-).Turn the LUX knob clockwise on the maximum (sun)
- Switch on the power; the sensor and its connected lamp will have no signal at the beginning. After
Warm-up 30sec, the sensor can start work .If the sensor receives the induction signal, the lamp will turn on.
While there is no another induction signal any more, the load should stop working within 10sec±3sec and the
lamp would turn off.
- Turn LUX knob anti-clockwise on the minimum (moon). If the ambient light is more than 3LUX, the sensor
would not work and the lamp stop working too. If the ambient light is less than 3LUX (darkness), the sensor
would work. Under no induction signal condition, the sensor should stop working within 10sec±3sec.
Note: when testing in daylight, please turn LUX knob to
If the lamp is more than 60W, the distance between lamp and sensor should be 60cm at least.
INSTRUCCIONES IMPORTANTES DE SEGURIDAD
(SUN) position, otherwise the sensor lamp could not work!
-9-
FIG. 2