5. Slide the tank drawer out and place the LP tank in the drawer. Connect the regulator as
shown in Figure 6. Turn the black handle clock-wise to tighten. Turn the handle counter
clock-wise to remove. The hose must point down. Check that the valve is turned all the
way clockwise to the "OFF" position. Open the tank valve. Apply a solution of soapy water
to the tank-regulator connection and to the valve-hose connection to check for leaks. If
soap bubbles continue to form, the connection has a leak. If a leak is found, close the tank
valve and tighten all connections.
NEVER USE A FLAME TO CHECK FOR LEAKS.
Figure 6
6. Tighten threaded knobs (L) found on tank tray (Figure 7) so that the LP tank cannot
move from side to side. Do not remove plastic cap from end of threaded section.
Figure 7
Jul-01-2016
7